3 master frequency output (dfout), Master frequency output (dfout), Configuration – Lenze EVF9383 User Manual
Page 224: Function blocks master frequency output (dfout)
Configuration
Function blocks
Master frequency output (DFOUT)
8.2
8.2.3
l
8.2−8
EDSVF9383V EN 7.1−04/2012
8.2.3
Master frequency output (DFOUT)
The function block creates rectangular signals from an analog signal or
speed signal, which are output via X10. Alternatively, you can set the master
frequency output to a signal output at X8 or X9.
C0030
C0540
CTRL
DFOUT-AN-IN
C0547
C0541
DFOUT-DF-IN
C0549
C0542
C0548
C0544
DFOUT-SYN-RDY
DFOUT-OUT
DFOUT
C0545
1
0
2
3
4
5
X8
X9
X10
C0540
E5
X5
fb_dfout
Fig. 8.2−7
Digital frequency output (DFOUT)
Codes for parameter setting
Code
Possible settings
IMPORTANT
No.
Name
Lenze Selection
C0030 DFOUT const
3
0
256 inc/rev
Function block DFOUT
l
Setting of the constant
(increments per revolution) for
the master frequency output
X10
^
8.2−8
1
512 inc/rev
2
1024 inc/rev
3
2048 inc/rev
4
4096 inc/rev
5
8192 inc/rev
6
16384 inc/rev
Description