Configuration
Function blocks
Master frequency ramp−function generator (DFRFG)
8.2
8.2.4
l
8.2−14
EDSVF9383V EN 7.1−04/2012
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0758
s
CFG: IN
1000 FIXEDPHI−0
^ Selection list 4
Configuration of input signal,
function block DFRFG1
l
Speed/phase setpoint signal
^
8.2−13
C0759
s
CFG: QSP
1000 FIXED0
^ Selection list 2
Configuration of digital input
signal, function block DFRFG1
l
HIGH = quick stop active
C0760
s
CFG: STOP
1000 FIXED0
^ Selection list 2
Configuration of input signal,
function block DFRFG1
l
HIGH = Status of the profile
generator is maintained,
setpoint is saved
C0761
s
CFG: RESET
1000 FIXED0
^ Selection list 2
Configuration of input signal,
function block DFRFG1
l
HIGH = resetting the
integrators
C0764
0
1 Function block DFRFG1
l
Display of the signals linked in
C0759, C0760 and C0761
1 DIS: QSP
2 DIS: STOP
3 DIS: RESET
C0765 DIS: IN
−32767
{1 rpm}
32767 Function block DFRFG1
l
Display of the signal linked in
C0758