Lenze EVF9383 User Manual
Page 145
Adjusting the motor
Motor selection list
6.6
6.6.2
l
6.6−5
EDSVF9383V EN 7.1−04/2012
Temperature sensor
Motor type
C0090
U
N
[V]
C0089
f
N
[Hz]
C0088
I
r
[A]
C0087
n
N
[rpm]
C0081
P
N
[kW]
Lenze type
1
0
210
DXRAXX071−12−50
DXRAXX071−12
0.25
1410
0.9
50
400
Asynchronous
inverter − motor
(Star connection)
Thermal contact
211
DXRAXX071−22−50
DXRAXX071−22
0.37
1398
1.2
212
DXRAXX080−12−50
DXRAXX080−12
0.55
1400
1.7
213
DXRAXX080−22−50
DXRAXX080−22
0.75
1410
2.3
214
DXRAXX090−12−50
DXRAXX090−12
1.10
1420
2.7
215
DXRAXX090−32−50
DXRAXX090−32
1.50
1415
3.6
216
DXRAXX100−22−50
DXRAXX100−22
2.20
1425
4.8
217
DXRAXX100−32−50
DXRAXX100−32
3.00
1415
6.6
218
DXRAXX112−12−50
DXRAXX112−12
4.00
1435
8.3
219
DXRAXX132−12−50
DXRAXX132−12
5.50
1450
11.0
220
DXRAXX132−22−50
DXRAXX132−22
7.50
1450
14.6
221
DXRAXX160−12−50
DXRAXX160−12
11.00
1460
21.0
222
DXRAXX160−22−50
DXRAXX160−22
15.00
1460
27.8
223
DXRAXX180−12−50
DXRAXX180−12
18.50
1470
32.8
224
DXRAXX180−22−50
DXRAXX180−22
22.00
1456
38.8
225
30kW−ASM−50
˘
30.00
1470
52.0
50
400
Asynchronous
inverter − motor
(Star connection)
˘
226
37kW−ASM−50
˘
37.00
1470
66.0
227
45kW−ASM−50
˘
45.00
1480
82.0
228
55kW−ASM−50
˘
55.00
1480
93.0
229
75kW−ASM−50
˘
75.00
1480
132.0
230
75kW−ASM−50
˘
90.00
1480
132.0
250
DXRAXX071−12−87
DXRAXX071−12
0.43
2525
1.5
87
400
Asynchronous
inverter − motor
(Delta connection)
Thermal contact
251
DXRAXX071−22−87
DXRAXX071−22
0.64
2515
2.0
252
DXRAXX080−12−87
DXRAXX080−12
0.95
2515
2.9
253
DXRAXX080−22−87
DXRAXX080−22
1.3
2525
4.0
254
DXRAXX090−12−87
DXRAXX090−12
2.0
2535
4.7
255
DXRAXX090−32−87
DXRAXX090−32
2.7
2530
6.2
256
DXRAXX100−22−87
DXRAXX100−22
3.9
2535
8.3
257
DXRAXX100−32−87
DXRAXX100−32
5.35
2530
11.4
258
DXRAXX112−12−87
DXRAXX112−12
7.10
2545
14.3
259
DXRAXX132−12−87
DXRAXX132−12
9.7
2555
19.1
260
DXRAXX132−22−87
DXRAXX132−22
13.2
2555
25.4
261
DXRAXX160−12−87
DXRAXX160−12
19.3
2565
36.5
262
DXRAXX160−22−87
DXRAXX160−22
26.4
2565
48.4
263
DXRAXX180−12−87
DXRAXX180−12
32.4
2575
57.8
264
DXRAXX180−22−87
DXRAXX180−22
38.7
2560
67.4
265
30kW−ASM−87
˘
52.00
2546
90.0
87
400
Asynchronous
inverter − motor
(Delta connection)
˘
266
37kW−ASM−87
˘
64.00
2546
114.0
267
45kW−ASM−87
˘
78.00
2563
142.0
268
55kW−ASM−87
˘
95.00
2563
161.0
269
75kW−ASM−87
˘
130.00
2563
228.0
270
90kW−ASM−87
˘
156.00
2590
277.0
410
MDXMAXM−071−12−50
MDXMAXM−071−12
0.25
1400
0.82
50
400
Asynchronous
inverter − motor
(Star connection)
Thermal contact
411
MDXMAXM−071−32−50
MDXMAXM−071−32
0.37
1400
1.20
50
400
412
MDXMAXM−080−12−50
MDXMAXM−080−12
0.55
1400
1.60
50
400
413
MDXMAXM−080−32−50
MDXMAXM−080−32
0.75
1380
2.00
50
400
414
MDXMAXM−090−12−50
MDXMAXM−090−12
1.10
1410
2.60
50
400
415
MDXMAXM−090−32−50
MDXMAXM−090−32
1.50
1420
3.50
50
400
416
MDXMAXM−100−12−50
MDXMAXM−100−12
2.20
1400
5.60
50
400
417
MDXMAXM−100−32−50
MDXMAXM−100−32
3.00
1400
7.30
50
400
418
MDXMAXM−112−22−50
MDXMAXM−112−22
4.00
1430
8.50
50
400