Configuration, Code table – Lenze EVF9383 User Manual
Page 337

Configuration
Code table
8.5
l
8.5−49
EDSVF9383V EN 4.0−03/2006
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0808
−199.99
{0.01 %}
199.99 Function block PCTRL
l
Display of the signals linked in
C0801, C0802, C0803 and
C0804
See System
Manual
(extension)
1 DIS: SET
2 DIS: ACT
3 DIS: INFLU
4 DIS: ADAPT
C0809
Function block PCTRL
l
Display of the signals linked in
C0805 and C0806
1 DIS: INACT
2 DIS: I−OFF
C0810
s
^ Selection list 1
Configuration of analog input
signals, function block ASW1
See System
Manual
(extension)
1 CFG: IN
1000 FIXED0%
ASW1−IN1
2 CFG: IN
1000 FIXED0%
ASW1−IN2
C0811
s
CFG: SET
1000 FIXED0
^ Selection list 2
Configuration of digital input
signal, function block ASW1
l
LOW: signal at ASW1−IN1 is
output to ASW1−OUT
l
HIGH: signal at ASW1−IN2 is
output to ASW1−OUT
C0812
−199.99
{0.01 %}
199.99 Function block ASW1
l
Display of the signals linked in
C0810
1 DIS: IN
ASW1−IN1
2 DIS: IN
ASW1−IN2
C0813 DIS: SET
0
1 Function block ASW1
l
Display of the signal linked in
C0811
C0815
s
^ Selection list 1
Configuration of analog input
signals, function block ASW2
See System
Manual
(extension)
1 CFG: IN
1000 FIXED0%
ASW2−IN1
2 CFG: IN
1000 FIXED0%
ASW2−IN2
C0816
s
CFG: SET
1000 FIXED0
^ Selection list 2
Configuration of digital input
signal, function block ASW2
l
LOW: signal at ASW2−IN1 is
output to ASW2−OUT
l
HIGH: signal at ASW2−IN2 is
output to ASW2−OUT
C0817
−199.99
{0.01 %}
199.99 Function block ASW2
l
Display of the signals linked in
C0815
1 DIS: IN
ASW2−IN1
2 DIS: IN
ASW2−IN2
C0818 DIS: SET
0
1 Function block ASW2
l
Display of the signal linked in
C0816
C0820
s
^ Selection list 2
Configuration of digital input
signals, function block AND1
See System
Manual
(extension)
1 CFG: IN
1000 FIXED0
AND1−IN1
2 CFG: IN
1000 FIXED0
AND1−IN2
3 CFG: IN
1000 FIXED0
AND1−IN3
C0821
0
1 Function block AND1
l
Display of the signals linked in
C0820
See System
Manual
(extension)
1 DIS: IN
AND1−IN1
2 DIS: IN
AND1−IN2
3 DIS: IN
AND1−IN3