Configuration, Code table – Lenze EVF9383 User Manual
Page 353
Configuration
Code table
8.5
l
8.5−65
EDSVF9383V EN 4.0−03/2006
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C1330 PCTRL2 Tir
1.0
0.1
{0.1 s
6000.0 Acceleration time t
ir
, function
block PCTRL2
l
Acceleration time for the
setpoint
l
The acceleration time refers to
a setpoint change of 0 ... 100 %
See System
Manual
(extension)
C1331 PCTRL2 Tif
1.0
0.1
{0.1 s}
6000.0 Deceleration time t
if
, function
block PCTRL2
l
Deceleration time for the
setpoint
l
The deceleration time refers to
a setpoint change of 100 % ... 0
C1332 PCTRL2 Vp
1.0
0.1
{0.1 }
500.0 Gain V
p
, function block PCTRL2
See System
Manual
(extension)
C1333 PCTRL2 Tn
400
20
{1 ms}
99999 Integral−action time T
n
, function
block PCTRL2
Setting of reset time T
n
of PCTRL2
C1334 PCTRL2 Kd
0.0
0.0
{0.1 }
5.0 Differential component K
d
,
function block PCTRL2
C1335 bipolar/
unipolar
0
Sphere of action, function block
PCTRL2
0
Bipolar
l
Output value is limited to
−100 ... 100 %
See System
Manual
(extension)
1
Unipolar
l
Output value is limited to
0 ... 100 %
C1336 Tir overlay
1.0
0.1
{0.1 s}
6000.0 Fade−in time, function block
PCTRL2
l
Acceleration time of the ramp
generator
l
Controls the influence of the
process controller
See System
Manual
(extension)
C1337 Tif overlay
1.0
0.1
{0.1 s}
6000.0 Fade−out time, function block
PCTRL2
l
Deceleration time of the ramp
generator
l
Controls the influence of the
process controller
C1340
s
^ Selection list 1
Configuration of analog input
signals, function block PCTRL2
See System
Manual
(extension)
1 CFG: RFG−SET
1000 FIXED0%
l
The process setpoint is shown
at PCTRL2−SET with a starting
value via a ramp generator
l
PCTRL−RFG−LOAD = HIGH
activates the function
2 CFG: SET
1000 FIXED0%
l
Input for process value
l
Value range: ±200 %
3 CFG: ACT
1000 FIXED0%
l
Input for actual value
l
Value range: ±200 %
4 CFG: INFL
1000 FIXED0%
l
Evaluation (influence) of the
output signal
l
Value range: ±200 %