Optimising the operating behaviour
Motor magnetising current with vector control
6.11
6.11.4
l
6.11−10
EDSVF9383V EN 7.1−04/2012
Codes for parameter setting
Code
Possible settings
IMPORTANT
No.
Name
Lenze Selection
C0080 Vp field CTRL
0.50
0.00
{0.01 }
0.99 Influence on the motor
magnetising current selected
under C0095
l
Not effective with C0006 = 1
and C0025 > 1 at the same
time
l
Influence is effective from 0 Hz
to the frequency selected
under C1583
^ 6.6−1
C0095
s
Mot Io
à
0.0
{0.1 A}
1000.0 Motor magnetising current
à
dependent on C0086, C0088
and C0091
l
Change of C0086 sets C0095 to
the Lenze setting
l
Change of C0095 sets
C0086 = 0
^ 6.6−1
C1583 fset high
100.0
0
0.00
{0.01 %}
199.99 Alterations by Lenze service only!
Adaptation of the motor
magnetising current set in C0095
(with V/f characteristic control:
influence limit of the boost
correction; with vector control:
influence limit of the field
precontrol)
l
The output frequency is set up
to which the motor
magnetising current set in
C0095 is to have an effect.
l
C1583 = 100 %
¢ half the
rated motor frequency in
C0089
^