Configuration
Code table
8.5
l
8.5−28
EDSVF9383V EN 4.0−03/2006
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0465
s
®
^ Selection list 5
Function block − processing list
l
Defining the sequence in which
the function blocks are to be
processed internally
à
Depending on C0005.
Changing C0005 loads
assigned processing list
à
The displayed values apply to
C0005 = 1000
l
After changing the signal flow,
adapt the processing list in any
case. Otherwise the controller
may use the wrong signals!
l
The function blocks DIGIN,
DIGOUT, AIF−IN, CAN−IN, and
MCTRL are always processed
and do not have to be entered
in the list
1 FB list
200
DFIN
2 FB list
0
3 FB list
50
AIN1
4 FB list
0
5 FB list
0
6 FB list
55
AIN2
7 FB list
0
8 FB list
0
9 FB list
10250 R/L/Q
10 FB list
0
... ...
0
14 FB list
0
15 FB list
5250 NLIM1
16 FB list
5050 NSET
... ...
0
19 FB list
5700 ANEG1
... ...
0
22 FB list
10650 CMP1
... ...
0
25 FB list
70
AOUT1
... ...
0
28 FB list
75
AOUT2
... ...
0
31 FB list
250
DFOUT
... ...
0
41 FB list
25000 AIF−OUT
42 FB list
20000 CAN−OUT
... ...
...
50 FB list
0
C0466 CPU T remain
Remaining process time for
processing the function blocks
l
Display only
C0469
s
Fct STP key
2
0
inactive
Inactive
Determines the function which is
released when pressing
s on the
keypad
Changes are only active after
mains connection!
1
CINH
Inhibit controller:
2
qsp
Quick stop
C0470
0
{1}
255 Configuration of free control
codes for digital signals
l
The data words C0470 and
C0471 are in parallel and are
identical.
1 FCODE 8 Bit
0
FCODE bit 0−7
2 FCODE 8 Bit
0
FCODE bit 8−15
3 FCODE 8 Bit
0
FCODE bit 16−23
4 FCODE 8 Bit
0
FCODE bit 24−31
C0471 Configuration
of input
FCODE 32 Bit
0
0
{1}
4294967296 Free control code for digital
signals
l
The data words C0470 and
C0471 are in parallel and are
identical.