Configuration, Code table – Lenze EVF9383 User Manual
Page 335
Configuration
Code table
8.5
l
8.5−47
EDSVF9383V EN 4.0−03/2006
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0780
s
CFG: N
5250 NLIM1−OUT
^ Selection list 1
Configuration of analog input
signal, function block NSET
l
Main setpoint
See System
Manual
(extension)
C0781
s
CFG: N−INV
10251 R/L/Q−R/L
^ Selection list 2
Configuration of digital input
signal, function block NSET
l
HIGH: main setpoint (C0780) is
inverted
C0782
s
CFG: NADD
55
AIN2−OUT
^ Selection list 1
Configuration of analog input
signal, function block NSET
l
Additional setpoint
C0783
s
CFG:
NADD−INV
1000 FIXED0
^ Selection list 2
Configuration of digital input
signal, function block NSET
l
HIGH: additional setpoint
(C0783) is inverted
C0784
s
CFG: CINH−VAL
5001 MCTRL−NACT
^ Selection list 1
Configuration of analog input
signal, function block NSET
l
The signal is accepted by the
main setpoint integrator when
the controller is inhibited
C0785
s
CFG: SET
5000 MCTRL−nset2
^ Selection list 1
Configuration of analog input
signal, function block NSET
l
When NSET−LOAD = HIGH, the
signal is accepted by the main
setpoint integrator
C0786
s
CFG: LOAD
5001 MCTRL−QSP−OUT
^ Selection list 2
Configuration of digital input
signal, function block NSET
l
HIGH: The signal at NSET−SET is
accepted by the mains setpoint
integrator
l
Control of both ramp function
generators in special
situations, e.g. quick stop
C0787
s
^ Selection list 2
Configuration of digital input
signals, function block NSET
l
Activation of a fixed speed via
binary coding of the digital
input signals
l
For coding see description of
function block NSET
l
Parameter setting of the fixed
speeds (JOG setpoints) in
C0039
See System
Manual
(extension)
1 CFG: JOG
53
DIGIN3
NSET−JOG*1
2 CFG: JOG
1000 FIXED0
NSET−JOG*2
3 CFG: JOG
1000 FIXED0
NSET−JOG*4
4 CFG: JOG
1000 FIXED0
NSET−JOG*8
C0788
s
^ Selection list 2
Configuration of digital input
signals, function block NSET
l
Activation of additional
acceleration and deceleration
times for the mains setpoint
via binary coding of the digital
input signals
l
For coding see description of
function block NSET
l
Parameter setting of the times
in C0101 and 103
1 CFG: TI
1000 FIXED0
NSET−Ti*1
2 CFG: TI
1000 FIXED0
NSET−Ti*2
3 CFG: TI
1000 FIXED0
NSET−Ti*4
4 CFG: TI
1000 FIXED0
NSET−Ti*8