Configuration – Lenze EVF9383 User Manual
Page 261
Configuration
Function blocks
Internal motor control with vector control (MCTRL2)
8.2
8.2.7
l
8.2−45
EDSVF9383V EN 7.1−04/2012
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0093 Drive ident
Controller identification
l
Read only
0
Invalid
Defective power section
1
None
No power section
14
...
20
9335VC 400V
...
9383VC 400V
Display of the controller used
21
...
28
9334VC 500V
...
9383VC 500V
9321
...
9333
9321 VC
...
9333VC
C0094 Password
0
0
{1}
9999 Password
l
C0094 = 1 ... 9999: Free access
to the user menu only
^ 7.2−9
C0095
s
Mot Io
à
0.0
{0.1 A}
1000.0 Motor magnetising current
à
dependent on C0086, C0088
and C0091
l
Change of C0086 sets C0095 to
the Lenze setting
l
Change of C0095 sets
C0086 = 0
^ 6.6−1
C0105 QSP Tif
5.00
0.00
{0.01 s}
999.90 Quick stop deceleration time
l
The deceleration time refers to
a speed variation of C0011 ... 0
^
8.2−25
^
8.2−40
C0107 holding time
0.00
0.00
{0.01 s}
9999.90 Hold time for automatic DC
injection braking (Auto−GSB)
^
8.2−25
^
8.2−40
C0143 limit 2 kHz
0.0
0.0
{0.1 Hz}
20.0 Speed−dependent switching
threshold
l
Threshold for automatic
switching frequency reduction
l
The controller changes
automatically to 2 kHz when
this value falls below the
threshold
^
8.2−25
^
8.2−40
C0234 damp value
20
−100
{1 %}
100 Influence of the oscillation
damping, function block MCTRL
l
Minimising a tendency to
oscillation of the drive
l
Influences the tendency to
oscillation of the drive
l
When C0025 >1 and C0006 = 1,
C0234 is set to 0
^
8.2−25
^
8.2−40
C0235 damping
2
1
{1 ms}
600 Filter time of the oscillation
damping, function block MCTRL
l
Filter time for the internal
signal for oscillation damping
^
8.2−25
^
8.2−40
C0236 damp limit
1.0
0.0
{0.1 Hz}
20.0 Limit value of oscillation damping,
function block MCTRL
l
Limit value for the internal
signal of oscillation damping