Configuration – Lenze EVF9383 User Manual
Page 243
Configuration
Function blocks
Internal motor control with V/f characteristic control (MCTRL1)
8.2
8.2.6
l
8.2−27
EDSVF9383V EN 7.1−04/2012
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0018 fchop
6
Switching frequency of the
inverter
l
General rule: The lower the
switching frequency the
– lower the power loss
– higher the noise generation
– better the concentricity
factor
l
Observe derating indications
for high switching frequencies
l
The max. output frequency
(f
max
) is:
– fchop = 4 kHz
Þ
f
max
= 300 Hz
– fchop = 2 kHz
Þ
f
max
= 150 Hz
– fchop = 1 kHz
Þ
f
max
= 150 Hz
^ 6.9−1
1
1 kHz sin
loss−optimised
2
2 kHz sin
concentricity−opti
mised
3
4 kHz f_top
power−optimised
4
4 kHz sin
noise−optimised
6
4/2 kHz sin
noise/concentricit
y−optimised with
automatic
change−over to
low switching
frequency
C0021 slipcomp
à
−20.00
{0.01 %}
20.00 Slip compensation
à
Change of C0086, C0087 or
C0089 sets C0021 to the
calculated rated slip of the
motor
l
When changing over to the
vector control mode, C0021 is
set to 0
^
6.11−1
^
8.2−25
^
8.2−40
C0022 Imax current
à
0
{0.1 A}
− I
max
limit in motor mode
à
depending on C0086
^
6.6−14
C0023 Imax gen.
à
0
{0.1 A}
− I
max
limit in generator mode
à
depending on C0086
^
6.6−14
C0036 DC brk value
0.0
0.0
{0.1 A}
− Set DC braking current
à
depends on the controller
^
8.2−25
^
8.2−40
C0042 DIS: QSP
Quick stop
l
Display only
^
8.2−25
^
8.2−40
0
QSP inactive
Quick stop is not active
1
QSP active
Quick stop is active
C0050 MCTRL−NSET2
−100.00
{0.01 %}
100.00 Speed setpoint, function block
MCTRL
l
Display of the speed in [%] of
C0011
^
8.2−25
^
8.2−40
C0051 MCTRL−NACT
−36000
{1 rpm}
36000 Actual speed value, function block
MCTRL
l
Read only
^
8.2−25
^
8.2−40
C0052 MCTRL−Umot
0
{1 V}
800 Motor voltage, function block
MCTRL
l
Read only
l
MCTRL−VACT = 100 % = C0090
^
8.2−25
^
8.2−40
C0053 UG−VOLTAGE
0
{1 V}
900 DC−bus voltage, function block
MCTRL
l
Read only
l
MCTRL−DCVOLT = 100 % =
1000 V
^
8.2−25
^
8.2−40
C0054 Imot
0.0
{0.1 A}
5000.0 Actual motor current, function
block MCTRL
l
Read only
l
MCTRL−IACT = 100 % = C0022
^
8.2−25
^
8.2−40