Configuration, Code table – Lenze EVF9383 User Manual
Page 336
Configuration
Code table
8.5
l
8.5−48
EDSVF9383V EN 4.0−03/2006
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0789
s
CFG: RFG−0
1000 FIXED0
^ Selection list 2
Configuration of digital input
signal, function block NSET
l
HIGH: Guides the main
setpoint integrator to 0 via the
current T
i
times
See System
Manual
(extension)
C0790
s
CFG: RFG−STOP
1000 FIXED0
^ Selection list 2
Configuration of digital input
signal, function block NSET
l
HIGH: Keeps the main setpoint
integrator on its current value
C0798
−199.99
{0.01 %}
199.99 Function block NSET
l
Display of the signals linked in
C0783 and C0785
Read only: analog input signals of
NSET
See System
Manual
(extension)
1 DIS: CINH−VAL
2 DIS: SET
C0799 Input signals
0
1 Function block NSET
l
Display of the signals linked in
C0781, C0783, C0786, C0787,
C0788, C0789 and C0790
1 DIS: N−INV
2 DIS: NADD−INV
3 DIS: LOAD
4 DIS: JOG*1
5 DIS: JOG*2
6 DIS: JOG*4
7 DIS: JOG*8
8 DIS: TI*1
9 DIS: TI*2
10 DIS: TI*4
11 DIS: TI*8
12 DIS: RFG−0
13 DIS: RFG−STOP
C0800
s
CFG: SET
1000 FIXED0%
^ Selection list 1
Configuration of analog input
signal, function block PCTRL
l
Input for the process setpoint
l
Value range: ±200 %
See System
Manual
(extension)
C0801
s
CFG: ACT
1000 FIXED0%
^ Selection list 1
Configuration of analog input
signal, function block PCTRL
Configuration of analog input
signal of PCTRL1
l
Input for the actual value
l
Value range:
±200 %
C0802
s
CFG: INFLU
1000 FIXED0%
^ Selection list 1
Configuration of analog input
signal, function block PCTRL
l
Evaluation (influence) of the
output signal
l
Value range: ±200 %
C0803
s
CFG: ADAPT
1000 FIXED0%
^ Selection list 1
Configuration of analog input
signal, function block PCTRL
l
The gain V
p
can be changed via
the adaptation input
l
Value range: ±200 %
C0804
s
CFG: INACT
1000 FIXED0
^ Selection list 2
Configuration of digital input
signal, function block PCTRL
l
HIGH = deactivates the process
controller
C0805
s
CFG: I−OFF
1000 FIXED0
^ Selection list 2
Configuration of digital input
signal, function block PCTRL
l
HIGH = Switching off integral
action component
l
LOW = Switching on integral
action component