Configuration
Function blocks
Master frequency processing (DFSET)
8.2
8.2.5
l
8.2−20
EDSVF9383V EN 7.1−04/2012
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0529 Multip offset
1
−20000
{1}
20000 Offset multiplier, function block
DFSET
l
Multiplier for the phase offset
(C0252)
^
8.2−18
C0530 DF evaluation
0
0
with factor
With gearbox
factor
Master frequency evaluation,
function block DFSET
l
Evaluation of the setpoint
integrator
1
no factor
Without gearbox
factor
C0531 Act 0 div
1
1
{1}
16384 Actual zero pulse divisor, function
block DFSET
C0532 0−pulse/TP
1
1
0−pulse
Index pulse
Zero pulse / touch probe, function
block DFSET
l
Zero pulse of the feedback
system or touch probe
2
Touch probe
Touch probe
C0533 Vp denom
1
1
{1}
32767 Gain factor of denominator V
p
,
function block DFSET
C0534 0 pulse fct
0
Zero pulse function, function
block DFSET
l
Synchronising the drive
^
8.2−18
0
inactive
Inactive
1
Continuous
Continuous
synchronisation,
correction in the
shortest possible
way
2
Cont. switch
Continuous
synchronisation,
correction in the
shortest possible
way
After a LOW−HIGH signal to
DFSET−0−pulse, the zero track is
synchronised once
10
Once, fast way
One−time
synchronisation,
correction in the
shortest possible
way
11
Once, CW
One−time
synchronisation,
correction in
direction of
rotation to the
right
12
Once, CCW
One−time
synchronisation,
correction in
direction of
rotation to the left
13
Once, 2*0−pulse
One−time
synchronisation,
correction is
detected from
setpoint pulse and
actual pulse and
corrected to the
corresponding
direction
C0535 Set 0 div
1
1
{1}
16384 Desired zero pulse divisor,
function block DFSET
^
8.2−18