B.2.12 project data – jog mode – Festo Электромотор MTR-DCI User Manual
Page 257

B. Reference – Festo DeviceNet and FHPP
B-35
Festo P.BE-MTR-DCI-DN-EN en 1209a
B.2.12 Project data – Jog mode
Jog Mode Velocity Phase 2
FHPP
531
–
Var
uint32
rw
Description
Speed in phase 2 (quick travel) in [inc/s]
Value range:
MTR-DCI-32: 66000
MTR-DCI-42: 100000
MTR-DCI-52: 100000
MTR-DCI-62: 113400
Default:
MTR-DCI-32: 6600
MTR-DCI-42: 10000
MTR-DCI-52: 10000
MTR-DCI-62: 11340
Value is automatically entered when an axis type (PNU 1005/4) is selected.
CI
20EDh
21h
Array
uint32
rw
Additional subindices of object 20EDh see PNU 406
DeviceNet
69h
01h
1Fh
uint32
rw
Jog Mode Acceleration
FHPP
532
–
Var
uint32
rw
Description
Acceleration and deceleration in [inc/s
2]
Value range:
MTR-DCI-32/42:
40000...480000
MTR-DCI-52/62:
40000...240000
Default: 40000
Value is automatically entered when an axis type (PNU 1005/4) is selected.
CI
20EEh
21h
Array
uint32
rw
Additional subindices of object 20EEh see PNU 407 and 541
DeviceNet
69h
01h
20h
uint32
rw
Jog Mode Time Phase 1
FHPP
534
–
Var
uint32
rw
Description
Duration of phase 1 (slow travel) in [ms].
Value range: 0...+(2
32
-1). Default: 2000 (0x000007D0)
CI
20E9h
21h
Array
uint32
rw
DeviceNet
69h
01h
22h
uint32
rw