B. Reference – Festo DeviceNet and FHPP
B-19
Festo P.BE-MTR-DCI-DN-EN en 1209a
Device Control
FHPP
125
–
Var
uint8
rw
Description
Activates device control of the controller via the controller interface.
Corresponds to “HMI control” on the control panel and “FCT/HMI” in the FCT.
0 (0x00): Control via control interface OFF,
via HMI (control panel) and FCT ON
1 (0x01): Control via controller interface OFF (default)
CI
207Dh
00h
Var
uint8
rw
DeviceNet
64h
01h
0Eh
uint8
rw
HMI Control
FHPP
126
1...4
Var
uint8
ro
Description
Settings for the HMI control panel (for MTR-DCI-...-H2 only)
Only affects the values in the display: all parameters are stored in increments.
LCD Current
(LCD voltage)
126
1
0
ro
Value range: 1...5 (0x01 ... 0x05). Default: 5
LCD Contrast 126
2
1
ro
Value range: 0...63 (0x00 ... 0x3F). Default: 0
Measuring unit 126
3
2
CI: rw
Measuring unit system for the control panel. See object 20D0h.
1 (0x01): metric units of measurement (mm, mm/s, mm/s
2
)
4 (0x04): angular degrees
8 (0x08): revolutions
Scaling Factor 126
4
3
CI: rw
Number of decimal places. Fix = 2. See object 20D0h
CI
20FFh
01h...04h
Array
uint8
rw
DeviceNet
64h
01h
0Fh...12h
uint8
rw