Commissioning 5-46, Step/ description o data i data, Tab. 5/11: i/o data “fault handling – Festo Электромотор MTR-DCI User Manual
Page 144
5. Commissioning
5-46
Festo P.BE-MTR-DCI-DN-EN en 1209a
Step/
Description
O data
I data
Byte
B7 B6 B5 B4 B3 B2 B1 B0 Byte
B7 B6 B5 B4 B3 B2 B1 B0
3.1 Fault
Byte 1
OPM2 OPM1
LOCK
–
RESET BRAKE STOP ENABL
Byte 1
OPM2 OPM1 LOCK
24VL
FAULT WARN OPEN ENABL
CCON
x
x
x
0
x
x
x
x
SCON
x
x
x
x
1
x
x
x
Byte 2
–
CLEAR TEACH JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV TEACH
MC
ACK
HALT
CPOS
0
x
x
x
x
x
x
x
SPOS
x
x
x
x
x
0
x
x
3.2 Warning
Byte 1
OPM2 OPM1
LOCK
–
RESET BRAKE STOP ENABL
Byte 1
OPM2 OPM1 LOCK
24VL
FAULT WARN OPEN ENABL
CCON
x
x
x
0
x
x
x
x
SCON
x
x
x
x
x
1
x
x
Byte 2
–
CLEAR TEACH JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV TEACH
MC
ACK
HALT
CPOS
0
x
x
x
x
x
x
x
SPOS
x
x
x
x
x
0
x
x
3.3 Reset fault
with CCON.B3
(RESET)
Byte 1
OPM2 OPM1
LOCK
–
RESET BRAKE STOP ENABL
Byte 1
OPM2 OPM1 LOCK
24VL
FAULT WARN OPEN ENABL
CCON
0
x
x
0
F
x
x
1
SCON
0
x
0
1
0
0
0
0
Byte 2
–
CLEAR TEACH JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV TEACH
MC
ACK
HALT
CPOS
0
0
0
0
0
0
x
x
SPOS
x
0
0
0
0
1
0
1
3.4 Reset fault
with CCON.B0
(ENABLE)
Byte 1
OPM2 OPM1
LOCK
–
RESET BRAKE STOP ENABL
Byte 1
OPM2 OPM1 LOCK
24VL
FAULT WARN OPEN ENABL
CCON
0
x
x
0
0
x
x
N
SCON
0
x
0
1
0
0
x
0
Byte 2
–
CLEAR TEACH JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV TEACH
MC
ACK
HALT
CPOS
0
0
0
0
0
0
x
x
SPOS
x
0
0
0
0
1
x
x
0: 0 signal
1: 1 signal;
x: not relevant (any);
F: Edge positive
Tab. 5/11: I/O data “Fault handling”