B.1.2 object overview (class, attribute, instance) – Festo Электромотор MTR-DCI User Manual
Page 226
B. Reference – Festo DeviceNet and FHPP
B-4
Festo P.BE-MTR-DCI-DN-EN en 1209a
B.1.2
Object overview (class, attribute, instance)
The object model is used for data access via “Explicit Mess-
aging” over DeviceNet. The following tables contain all
defined parameters and specify the class (CLS), attribute
(ATTR) and instance (INST). For data addressing via the FPC
(within the cyclic I/O data), the FHPP parameter number/
sub-addressing is used.
The descriptions of the parameters can be found under the
specified FHPP parameter number PNU, in sections B.2.4 to
B.2.19.
Device Data
FHPP
Class 100 (0x64)
CLS
INST
ATTR PNU
SI
See
Manufacturer Hardware Version
64h
01h
01h
100
—
B.2.4
Manufacturer Firmware Version
64h
01h
02h
101
—
B.2.4
Version FHPP
64h
01h
03h
102
—
B.2.4
Controller Serial Number
64h
01h
08h
114
—
B.2.4
Manufacturer Device Name
64h
01h
09h
120
—
B.2.5
User Device Name
64h
01h
1Ah
121
—
B.2.5
Drive Manufacturer
64h
01h
1Bh
122
—
B.2.5
HTTP Drive Catalogue Address
64h
01h
1Ch
123
—
B.2.5
Festo Order Number
64h
01h
1Dh
124
—
B.2.5
Device Control
64h
01h
1Eh
125
—
B.2.5
HMI Control
–
LCD Voltage
64h
01h
1Fh
126
1
B.2.5
–
LCD Contrast
64h
01h
10h
126
2
B.2.5
–
Unity
64h
01h
11h
126
3
B.2.5
–
Scale
64h
01h
12h
126
4
B.2.5
Keypad Status
64h
01h
13h
306
—
B.2.7