5. Commissioning
5-53
Festo P.BE-MTR-DCI-DN-EN en 1209a
Step/
Description
O data
I data
Byte
B7 B6 B5 B4 B3 B2 B1 B0 Byte
B7 B6 B5 B4 B3 B2 B1 B0
7.1 Specify nominal
value
4
Not relevant
4
Actual value in % of the nominal
current
5...8
Nominal value in % of the nominal
current
5...8
Actual positions in increments
7.2 Preparing for
Force mode
Byte 1
OPM2 OPM1
LOCK
–
RESET BRAKE STOP
ENABL
Byte 1
OPM2 OPM1 LOCK
24VL
FAULT WARN OPEN ENABL
CCON 0
1
x
x
0
x
1
1
SCON 0
1
0
1
0
0
1
1
Byte 2
–
CLEAR TEACH JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV TEACH
MC
ACK
HALT
CPOS x
0
0
0
0
0
0
1
SPOS 1
0
0
0
0
1
0
1
Byte 3
FUNC
FAST
XUM
–
CONT COM2 COM1
ABS
Byte 3
FUNC
FAST
XUM
VUM
CONT COM2 COM1
ABS
CDIR
0
0
S
x
0
0
1
0
SDIR
0
0
0
x
0
0
0
0
7.3 Start task
Byte 1
OPM2 OPM1
LOCK
–
RESET BRAKE STOP
ENABL
Byte 1
OPM2 OPM1 LOCK
24VL
FAULT WARN OPEN ENABL
CCON 0
1
x
x
0
x
1
1
SCON 0
1
0
1
0
0
1
1
Byte 2
–
CLEAR TEACH JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV TEACH
MC
ACK
HALT
CPOS x
0
0
0
0
0
F
1
SPOS 1
0
0
0
0
0
1
1
Byte 3
FUNC
FAST
XUM
–
CONT COM2 COM1
ABS
Byte 3
FUNC
FAST
XUM
VUM
CONT COM2 COM1
ABS
CDIR
0
0
S
x
0
0
1
0
SDIR
0
0
0
0
0
0
1
0
7.4 Positioning task
in progress
(nominal value not
reached)
Byte 1
OPM2 OPM1
LOCK
–
RESET BRAKE STOP
ENABL
Byte 1
OPM2 OPM1 LOCK
24VL
FAULT WARN OPEN ENABL
CCON 0
1
x
x
0
x
1
1
SCON 0
1
0
1
0
0
1
1
Byte 2
–
CLEAR TEACH JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV TEACH
MC
ACK
HALT
CPOS x
0
0
0
0
0
x
1
SPOS 1
0
0
1
0
0
x
1
Byte 3
FUNC
FAST
XUM
–
CONT COM2 COM1
ABS
Byte 3
FUNC
FAST
XUM
VUM
CONT COM2 COM1
ABS
CDIR
0
0
S
x
0
0
1
0
SDIR
0
0
0
1
0
0
1
0
7.5 Positioning task
in progress
(nominal value
reached)
Byte 1
OPM2 OPM1
LOCK
–
RESET BRAKE STOP
ENABL
Byte 1
OPM2 OPM1 LOCK
24VL
FAULT WARN OPEN ENABL
CCON 0
1
x
x
0
x
1
1
SCON 0
1
0
1
0
0
1
1
Byte 2
–
CLEAR TEACH JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV TEACH
MC
ACK
HALT
CPOS x
0
0
0
0
0
x
1
SPOS 1
0
0
0
0
1
x
1
Byte 3
FUNC
FAST
XUM
–
CONT COM2 COM1
ABS
Byte 3
FUNC
FAST
XUM
VUM
CONT COM2 COM1
ABS
CDIR
0
0
S
x
0
0
1
0
SDIR
0
0
0
0
0
0
1
0