Commissioning 5-51, Step/ description o data i data, Tab. 5/14: i/o data “direct task: positioning mode – Festo Электромотор MTR-DCI User Manual
Page 149
5. Commissioning
5-51
Festo P.BE-MTR-DCI-DN-EN en 1209a
Step/
Description
O data
I data
Byte
B7 B6 B5 B4 B3 B2 B1 B0 Byte
B7 B6 B5 B4 B3 B2 B1 B0
6.1 Preselect position
and speed
(bytes 4 and 5...8)
Byte 4
Velocity
Byte 4
Velocity
Speed
Speed preselection
(0...100 %)
Speed
Speed response message
(0...100 %)
Byte 5...8
Position
Byte 5...8
Position
Nom-
inal
posi-
tion
Nominal position
(increments),
see section 5.5.2
Actual
posi-
tion
Actual position (increments),
see section 5.5.2
6.2 Start task
Byte 1
OPM2 OPM1
LOCK
–
RESET BRAKE STOP
ENABL
Byte 1
OPM2 OPM1 LOCK
24VL
FAULT WARN OPEN ENABL
CCON
0
1
x
0
0
x
1
1
SCON
0
1
0
1
0
0
1
1
Byte 2
–
CLEAR TEACH JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV TEACH
MC
ACK
HALT
CPOS
0
0
0
0
0
0
F
1
SPOS
1
0
0
0
0
0
1
1
Byte 3
FUNC
FAST
XLIM
VLIM
CONT COM2 COM1
ABS
Byte 3
FUNC FAST
XLIM
VLIM
CONT COM2 COM1
ABS
CDIR
0
0
0
0
0
0
0
S
SDIR
0
0
0
0
0
0
0
S
6.3. Positioning task
in progress
Byte 1
OPM2 OPM1
LOCK
–
RESET BRAKE STOP
ENABL
Byte 1
OPM2 OPM1 LOCK
24VL
FAULT WARN OPEN ENABL
CCON
0
1
x
0
0
x
1
1
SCON
0
1
0
1
0
0
1
1
Byte 2
–
CLEAR TEACH JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV TEACH
MC
ACK
HALT
CPOS
0
0
0
0
0
0
1
1
SPOS
1
0
0
1
0
0
1
1
6.4 Positioning task
concluded
Byte 1
OPM2 OPM1
LOCK
–
RESET BRAKE STOP
ENABL
Byte 1
OPM2 OPM1 LOCK
24VL
FAULT WARN OPEN ENABL
CCON
0
1
x
0
0
x
1
1
SCON
0
1
0
1
0
0
1
1
Byte 2
–
CLEAR TEACH JOGN
JOGP
HOM
START
HALT
Byte 2
REF
STILL
DEV
MOV TEACH
MC
ACK
HALT
CPOS
0
0
0
0
0
0
0
1
SPOS
1
0
0
0
0
1
0
1
0: 0 signal
1: 1 signal;
x: not relevant (any);
F: Edge positive
S: Positioning condition: 0= absolute; 1 = relative