CH9: Diagnostics
MAN0575-04-EN
PAGE 73 of 97
© Horner APG.This drawing is the property of Horner APG. And shall not be disclosed or reproduced except as specifically authorised.
Profibus Modules User Manual
EO 09-0009
Figure 56: Save a Message
10.3
Message Monitor for Testing of DPV1 (Master)
The following steps show how to configure the Message Monitor for reading and writing via DPV1
from the Master:
Enter the following in the Message Monitor in order to read data via DPV1 from a Slave:
Message for Read via DPV1
Message header
Rx = 3 (always)
Tx = 255
Ln = (calculated)
Nr = 0 .. 255
A = 0
F = 0
B = 17
E = 0
Telegram header
Meaning for DPV1
Value range
Device Adr
Station address of the Slave 0 .. 126
Data Area
Unused
0
Data Address
Slot
0 .. 254
Data Index
Index
0 .. 255
Data Count
Data Count
1 .. 240
Data Type
Data Type
10
Function Read
1
Table 16: Message Monitor – Example DPV 1 Read
The following must be entered in the Message Monitor in order to write data via DPV1 to a Slave:
Message for Write via DPV1
Message header
Rx = 3 (always)
Tx = 255
Ln = (calculated)
Nr = 0 .. 255
A = 0
F = 0