Figure 32 configure fabric parameters dialog box, Fabric parameters, R_a_tov – HP StorageWorks 2.140 Director Switch User Manual
Page 95: E_d_tov, 32 configure fabric parameters dialog box

Director Element Manager user guide
95
2.
Select Configure > Operating Parameters > Fabric Parameters.
The Configure Fabric Parameters dialog box is displayed, as shown in
Figure 32
Configure Fabric Parameters dialog box
3.
Use information in the next section, ”
” on page 95, to change settings as
required for parameters in this dialog box.
4.
After you change settings, click Activate.
5.
Back up the configuration data when you are finished configuring the director.
6.
Set the director on line. For instructions, see ”
Fabric Parameters
Configure the following parameters as required by your fabric.
R_A_TOV
Resource allocation time-out value. This variable is used to time out operations that depend on the
maximum possible time that a frame can be delayed in a fabric and still be delivered. Adjust the
value for R_A_TOV in tenths of a second (100 ms) increments over a range of 10 tenths (1 second)
to 1200 tenths (120 seconds). The default value is 100 tenths (10 seconds).
NOTE:
Set the same value for R_A_TOV on all switches on a multiswitch fabric. If the value is not
the same on all units, the fabric segments. Also, the value for R_A_TOV must be greater than the
value configured for E_D_TOV.
E_D_TOV
Error-detect time-out value. This variable defines the time that the switch waits for an expected
response before declaring an error condition. Configure this value in tenths of a second (100 ms)
increments in a range of 2 tenths of a second to 600 tenths (60 seconds). The default value is 20
tenths (2 seconds).
NOTE:
Set the same value for E_D_TOV on all switches on a multiswitch fabric. If the value is not
the same on all units, the fabric segments.