beautypg.com

Table 6 event codes, 6 event codes – HP StorageWorks 2.140 Director Switch User Manual

Page 154

background image

Using logs

154

Each log entry includes the following:

Date/Time—The date and time of the event on the director

Event—Events are identified by a unique code.

Table 6

lists the event codes and their

corresponding event types.

The Event column may also display the following acronyms to describe the port card:

GLSL

—G_Port, long wave, single-mode LC connector, 1 Gigabit

GSML

—G_Port, short wave, multi-mode, LC connector, 1 Gigabit

GXXL

—G_Port, mixed mode, LC connector, 1 Gigabit

FPM

—G_Port, small form factor pluggable (SFP) optics, FICON port module, 1 Gigabit

UPM

—G_Port, small form factor pluggable (SFP) optics, universal port module, 2 Gigabit

GSF2

—G_Port, small form factor pluggable (SFP) optics, universal port module, 2 Gigabit

GLSR

—G_Port, short wave, single-mode, MT-RJ connector, 1 Gigabit

GXXR

—G_Port, mixed mode, MT-RJ connector, 1 Gigabit

GSMR

—G_Port, short wave, multi-mode, MT-RJ connector, 1 Gigabit

The chassis (slot) position for a non-redundant FRU is 0. The chassis positions for redundant FRUs

are 0, 1, and 2. The chassis positions for port cards are 0 through 35, and slot 32 is

unavailable.

Description—A short description of the event

Severity—One of the following classifications of severity that identify the importance of the

event:
• 0=Informational
• 2=Warning
• 3=Fatal
• 4=Fatal, not operational

Table 6

Event codes

Code

Event

000–199

System events

200–299

Power supply events

300–399

Fan module events

400–499

CTP card events

500–599

Port card events

600–699

SBAR card events

800–899

Thermal events

This manual is related to the following products: