Configuring the director

94

Director Speed (Director 2/64 only)

NOTE:

To change this value, you must first set the director off line. Be sure to set the director back

on line after you change this value.

When setting the director speed, consider the following:

Configure port speeds individually through the Configure Ports dialog box. You cannot set a

director speed to less than the port speeds. If you set the director speed to

1 Gig

and at least

one port is configured at

2 Gig,

an error message is displayed stating that you cannot modify

the director speed.

If you set the director data speed to

2 Gig

, all installed CTP cards must support 2 Gb/s data

speeds or an error message is displayed stating that you cannot modify the director speed.

When you change the speed to

2 Gig

, all ports on Fibre Channel port module (FPM) cards go

to an inactive state. A warning/confirmation message is displayed, allowing you to continue the

operation or cancel. Only universal port module (UPM) cards allow 1 Gb/s and 2 Gb/s

operation.

Director firmware must support the 2 Gb/s data rate. If you set the speed to

2 Gig

and the

firmware only supports 1 Gb/s, an error message is displayed stating that the feature is not

supported and providing the firmware level that will support the higher speed.
At the Director Speed field, click 1 Gig or 2 Gig to select the speed of Fibre Channel operation.

NOTE:

Changing the director speed to 2 Gb/s with any 1 Gb/s FPM card installed will

cause the following warning/confirmation message to display:

All FPM ports will be

held inactive while the director is configured to 2 Gb/sec speed.

Do you want to continue?

Configuring fabric parameters

Use procedures in this section to set parameters on the director for fabric operation through the

Configure Fabric Parameters dialog box. These operating parameters are stored in NV-RAM on the

switch.

1.

Verify that the director is set off line. For instructions, see ”

Setting on line state

” on page 170.

CAUTION:

Setting the director off line terminates all Fibre Channel connections.