HP StorageWorks 2.140 Director Switch User Manual
Page 52

Monitoring and managing the director
52
•
Corresponding or additional descriptions of hardware status and states also display when you
click components to display Properties dialog boxes.
NOTE:
See
for the indicators.
Figure 12
Hardware operation-Director Hardware view
•
Port card attention indicator 1—The yellow triangle status symbol ( ) on the port card indicates
that the port card is in a degraded state. This could indicate a problem with an individual port,
such as a link failure or service-required status. A yellow triangle could also indicate that a port
is in beaconing state. Open the Port Card view by double-clicking the port card to examine
individual port status. See ”
” on page 61 for details.
•
Port card failure indicator 2—The blinking red and yellow diamond ( ) on the port card with
the amber port card LED illuminated may indicate that the card has failed. This may also
indicate that an individual port has failed on the card. Open the Port Card view by clicking the
port card to examine individual port status. If an individual port has not failed, the card is at
fault.
1
Port attention indicator
2
Port LED indicator
3
Port failure indicator
4
Beaconing
5
Not installed
6
Power, system error, and unit beaconing indicators
7
Power supply status