Hardware log, Figure 70 hardware log, Table 7 fru names – HP StorageWorks 2.140 Director Switch User Manual
Page 155: 70 hardware log, 7 fru names
Director Element Manager user guide 155
•
FRU Position—An acronym representing the FRU type, followed by a number representing the
FRU chassis position. FRU acronyms are:
• CTP—CTP card
• FAN—fan module
• PWR—power supply
The chassis (slot) position for a non-redundant FRU is 0. The chassis positions for redundant
FRUs are 0, 1, and 2. The chassis positions for port cards are 0 through 35, and slot 32 is
unavailable.
•
Event Data—Up to 32 bytes of supplementary information for the event in hexadecimal format.
For detailed information on event data and problem resolution, see the event code tables
appendix in the McDATA Intrepid Director 6064 Installation and Service Manual for the Director
2/64 and the McDATA Intrepid Director 6140 Installation and Service Manual for the Director
2/140.
Hardware Log
The Hardware Log displays information on FRUs inserted and removed from the director.
Figure 70
Hardware Log
Each log entry includes the following:
•
Date/Time—Date and time of the insertion or removal of the FRU
•
FRU—The name of the inserted or removed FRU
Table 7
FRU names
FRU Code
FRU Name
FAN
Fan module
PWR
Power supply module