HP StorageWorks 2.140 Director Switch User Manual
Page 31
![background image](/manuals/398914/31/background.png)
Director Element Manager user guide
31
• Open Systems Management Style—For each port you can provide a name, block or
unblock operation, configure extended distance buffering for 10 to 100 km, enable LIN
alerts for each port, define a type (G, F, or E), set the speed, enable Port Binding, and enter
a WWN or nickname.
NOTE:
Ports are automatically configured as G_Ports if no device is connected, F_Ports if a
device is connected, and E_Ports if a director is connected.
In both styles, you can enable the rerouting delay feature, and for the Director 2/64 only, you
can set the director data speed.
NOTE:
Note that your director model and firmware may not allow variable data speeds.
•
Allow/Prohibit Matrix (FICON Management only)—Select one of the following
options:
• Active Addresses—Displays the Configure-Addresses—“Active” dialog box. Use this dialog
box to configure a name, blocked or unblocked state, and prohibited and allowed
connection attributes for a port.
• Stored Addresses—Displays the Address Configuration Library. Use this dialog box to
activate, modify, delete, and modify existing address configurations created through the
Active Addresses dialog box.
•
SNMP Agent—Displays the Configure SNMP dialog box. Use this dialog box to:
• Configure network addresses and community names for up to six SNMP trap recipients.
• Authorize write permissions to enable SNMP management stations to modify writable MIB
variables.
• Enable authorization traps to be sent to management stations when unauthorized stations
request access to director SNMP data.
•
FICON Management Server—Displays if the FICON Management Server in-band
management feature was enabled through the Configure Feature Key dialog box. (See
” on page 136 for more information.) You can select the following
suboptions:
• Enable FMS—Displays a check mark and enables the FICON Management Server.
• Parameters—Displays the Configure FICON Management Server dialog box. Use this
dialog box to perform the following tasks:
• Allow or prohibit director clock alert mode.
• Allow or prohibit programmed off line state control.
• Select a code page from the Code Page list.
For details, see ”
•
Open Systems Management Server—Displays if the Open Systems Management Server
in-band management feature was enabled through the Configure Feature Key dialog box. (See