Director Element Manager user guide
53
See ”
” on page 61 for details on using the Port Card view. See ”
” on page 84 for details on port operating states and the status symbol and indicator
operation.
•
CTP card failure indicator 3—The blinking red and yellow diamond ( ) on the CTP card with
the amber LED illuminated indicates that the card has failed.
•
Active CTP card indicator 4—The green LED on a CTP card illuminates to indicate that the card
is active. Since the redundant CTP card on the left has failed, this CTP card has become the
active card. If both CTP cards are operational, no LEDs illuminate on the backup card, while the
green LED illuminates on the active CTP card.
•
Power, system error, and unit beaconing indicators 5—The green and amber indicators on the
far right of the front bezel simulate the power and system error LEDs on the actual director bezel.
• Power indicator—The green indicator simulates the power LED on the actual director. When
the indicator illuminates, the director is connected to facility AC power and is operational.
The indicator will be on if either power supply is operating.
• System error indicator—The amber system error light indicator (illuminated in the Hardware
views as shown in
on page 36 and
Figure 13
on page 50) simulates the system
error light on the actual director. When this indicator illuminates, an event has occurred
requiring immediate attention, such as a system, fan, power supply, or port failure. View
details of system errors by choosing Event Log from the Logs menu on the menu bar. The
indicator in the Hardware view and the LED on the actual unit remain illuminated until you
clear the event by right-clicking on the director graphic, away from a FRU, and choosing
Clear System Error Light from the pop-up menu.
NOTE:
If the amber LED flashes, this indicates that unit beaconing has been enabled for the
director. Enable or disable unit beaconing by right-clicking on the director graphic, away
from a FRU, and choosing Enable Unit Beaconing from the pop-up menu.
•
Power supply failure indicator 6—When a blinking red and yellow diamond ( ) is displayed
on a power supply with the amber Fault indicator illuminated, the power supply has failed. The
backup power supply has taken over to supply DC voltage to the director.
NOTE:
A green indicator is displayed and no status symbols display if the power supply is
working, as shown on the left in
•
Cooling fan module failure indicator 7—When a blinking red and yellow diamond ( ) is
displayed on a fan module with the amber LED indicator illuminated, the module has failed or is
rotating insufficiently.
•
SBAR card beaconing indicator 8—The yellow triangle status symbol ( ) displaying on the
SBAR card, with the amber LED illuminated, indicates that beaconing has been enabled.
•
SBAR failure indicator 9—The blinking red and yellow diamond ( ) displaying on the SBAR
card with the amber LED illuminated indicates a card failure.