HP StorageWorks 2.140 Director Switch User Manual

Page 53

background image

Director Element Manager user guide

53

See

Port Card view

” on page 61 for details on using the Port Card view. See ”

Port operational

states

” on page 84 for details on port operating states and the status symbol and indicator

operation.

CTP card failure indicator 3—The blinking red and yellow diamond ( ) on the CTP card with

the amber LED illuminated indicates that the card has failed.

Active CTP card indicator 4—The green LED on a CTP card illuminates to indicate that the card

is active. Since the redundant CTP card on the left has failed, this CTP card has become the

active card. If both CTP cards are operational, no LEDs illuminate on the backup card, while the

green LED illuminates on the active CTP card.

Power, system error, and unit beaconing indicators 5—The green and amber indicators on the

far right of the front bezel simulate the power and system error LEDs on the actual director bezel.
Power indicator—The green indicator simulates the power LED on the actual director. When

the indicator illuminates, the director is connected to facility AC power and is operational.

The indicator will be on if either power supply is operating.

System error indicator—The amber system error light indicator (illuminated in the Hardware

views as shown in

Figure 5

on page 36 and

Figure 13

on page 50) simulates the system

error light on the actual director. When this indicator illuminates, an event has occurred

requiring immediate attention, such as a system, fan, power supply, or port failure. View

details of system errors by choosing Event Log from the Logs menu on the menu bar. The

indicator in the Hardware view and the LED on the actual unit remain illuminated until you

clear the event by right-clicking on the director graphic, away from a FRU, and choosing

Clear System Error Light from the pop-up menu.

NOTE:

If the amber LED flashes, this indicates that unit beaconing has been enabled for the

director. Enable or disable unit beaconing by right-clicking on the director graphic, away

from a FRU, and choosing Enable Unit Beaconing from the pop-up menu.

Power supply failure indicator 6—When a blinking red and yellow diamond ( ) is displayed

on a power supply with the amber Fault indicator illuminated, the power supply has failed. The

backup power supply has taken over to supply DC voltage to the director.

NOTE:

A green indicator is displayed and no status symbols display if the power supply is

working, as shown on the left in

Figure 5

on page 36 and

Figure 6

on page 37.

Cooling fan module failure indicator 7—When a blinking red and yellow diamond ( ) is

displayed on a fan module with the amber LED indicator illuminated, the module has failed or is

rotating insufficiently.

SBAR card beaconing indicator 8—The yellow triangle status symbol ( ) displaying on the

SBAR card, with the amber LED illuminated, indicates that beaconing has been enabled.

SBAR failure indicator 9—The blinking red and yellow diamond ( ) displaying on the SBAR

card with the amber LED illuminated indicates a card failure.