HP StorageWorks 2.140 Director Switch User Manual
Page 66
Monitoring and managing the director
66
0x0E Authorization Failure
Reject
The switch on the other side of the ISL detected a security
violation. This switch receives notification via a generic
reject reason code and sets its port to the invalid
attachment state in sympathy.
0x0F Unauthorized Switch
Binding WWN
A Switch Binding error was detected on either an E_Port
or an F_Port.
0x10 Authentication Failure
ISL Authentication Check (CHAP) failed—If you wish to
allow the connection, update the authentication lists or
disable authentication.
0x11 Fabric Mode Mismatch
A connection was not allowed because:
An HP M-Series switch or director attempted to connect to
an HP switch or director running in Open Fabric mode.
An HP M-Series switch or director running in Open Fabric
mode attempted to connect to another vendor’s switch or
director with an incorrect ELP revision level.
0x12 CNT WAN Extension Mode
Mismatch
The ELP maximum frame sizes were incompatible because
one product running in CNT WAN extension mode
attempted to connect to another product running in a
normal mode.
Segmented E_Port messages
Incompatible operating
parameters, such as resource
allocation time-out values
(R_A_TOV) or error-detect
time-out values (E_D_TOV) are
inconsistent
See ”
Configuring operating parameters” on page 91
for
more information.
Duplicate domain IDs
See ”
Configuring operating parameters” on page 91
for
more information.
Incompatible zoning
configurations
See the McDATA Products in a SAN Environment
Planning Manual for information on fabrics and on
joining zoned fabrics.
Build fabric protocol error
.
No principal switch (no switch
in fabric is capable of being
the principal switch)
.
No response from an attached
switch.
Table 4
Messages in the Port Properties dialog box Reason field (continued)
Message
Description