HP StorageWorks 2.140 Director Switch User Manual
Page 124
![background image](/manuals/398914/124/background.png)
Configuring the director
124
1.
Select Configure > Ports on the Element Manager menu bar.
The Configure Ports dialog box is displayed, as shown in
.
Figure 45
Configure Ports dialog box (Open Systems management style)
Ports are numbered from 0–63 on the Director 2/64, and 0–127 and 132–143 on the Director
2/140.
NOTE:
Director 2/140, ports 128–131 are internal ports and not available for external
connections.
2.
Type a name that reflects the end device connected through the port in the Name field.
For example, use
XYZ Server
, where
XYZ
is the brand name of the server.
3.
Click the check box in the Blocked column to block or unblock operation for a port.
4.
Click the check box in the 10-100 km column to enable or disable extended distance buffering
for the port.
5.
If a director supports BB Credit, the RX BB Credit column replaces the 10-100km column.
Use this to set minimum and maximum allowable port BB credit values as follows: