Configuring the director

124

1.

Select Configure > Ports on the Element Manager menu bar.

The Configure Ports dialog box is displayed, as shown in

Figure 45

.

Figure 45

Configure Ports dialog box (Open Systems management style)

Ports are numbered from 0–63 on the Director 2/64, and 0–127 and 132–143 on the Director

2/140.

NOTE:

Director 2/140, ports 128–131 are internal ports and not available for external

connections.

2.

Type a name that reflects the end device connected through the port in the Name field.

For example, use

XYZ Server

, where

XYZ

is the brand name of the server.

3.

Click the check box in the Blocked column to block or unblock operation for a port.

4.

Click the check box in the 10-100 km column to enable or disable extended distance buffering

for the port.

5.

If a director supports BB Credit, the RX BB Credit column replaces the 10-100km column.

Use this to set minimum and maximum allowable port BB credit values as follows: