HP StorageWorks 2.140 Director Switch User Manual
Page 83
![background image](/manuals/398914/83/background.png)
Director Element Manager user guide
83
Information on the FRU List view for each FRU includes:
•
FRU—A description of the FRU type, as follows:
• Backplane
• Control Processor (CTP)
• Serial Crossbar (SBAR)
• G Port Module—For the fiber channel port card, the following acronyms may display to
indicate the card’s port technology:
• GLSL—G_Port, long wave, single mode LC connector, 1 gigabit
• GSML—G_Port, short wave, multimode, LC connector, 1 gigabit
• GXXL—G_Port, mixed mode, LC connector, 1 gigabit
• FPM—G_Port, small form factor pluggable (SFP) optics, fiber port module, 1 gigabit
• UPM—G_Port, small form factor pluggable (SFP) optics, universal port module, 2 gigabit
• GSFM—G_Port, short wave, small form factor, multimode, 1 gigabit
• GLSR—G_Port, short wave, single mode, MT-RJ connector, 1 gigabit
• GXXR—G_Port, mixed mode, MT-RJ connector, 1 gigabit
• GXXL—G_Port, mixed mode, LC connector, 1 gigabit
• Cooling FAN—Fan module.
• PWR—Power supply module.
•
Position—A number representing the FRU chassis position. The chassis (slot) position for a
nonredundant FRU is 0. The chassis positions for redundant FRUs are 0 and 1. For the Director
2/64 chassis, port positions are 0–63. For the Director 2/140 model, port positions are 0–127
and 132–143. Note that for the Director 2/140, ports 128–131 are internal ports and are not
available for external connections.
•
Status—The FRU status (Active or Backup).
•
Part Number—The FRU part number.
•
Serial Number—The FRU serial number.
To display the FRU Properties dialog box for a FRU, do one of the following:
•
Click the FRU’s row and select Product > FRU > FRU Properties.
•
Double-click a FRU.