Director Element Manager user guide

83

Information on the FRU List view for each FRU includes:

FRU—A description of the FRU type, as follows:
• Backplane
• Control Processor (CTP)
• Serial Crossbar (SBAR)
G Port Module—For the fiber channel port card, the following acronyms may display to

indicate the card’s port technology:
• GLSL—G_Port, long wave, single mode LC connector, 1 gigabit
• GSML—G_Port, short wave, multimode, LC connector, 1 gigabit
• GXXL—G_Port, mixed mode, LC connector, 1 gigabit
• FPM—G_Port, small form factor pluggable (SFP) optics, fiber port module, 1 gigabit
• UPM—G_Port, small form factor pluggable (SFP) optics, universal port module, 2 gigabit
• GSFM—G_Port, short wave, small form factor, multimode, 1 gigabit
• GLSR—G_Port, short wave, single mode, MT-RJ connector, 1 gigabit
• GXXR—G_Port, mixed mode, MT-RJ connector, 1 gigabit
• GXXL—G_Port, mixed mode, LC connector, 1 gigabit

Cooling FAN—Fan module.
PWR—Power supply module.

Position—A number representing the FRU chassis position. The chassis (slot) position for a

nonredundant FRU is 0. The chassis positions for redundant FRUs are 0 and 1. For the Director

2/64 chassis, port positions are 0–63. For the Director 2/140 model, port positions are 0–127

and 132–143. Note that for the Director 2/140, ports 128–131 are internal ports and are not

available for external connections.

Status—The FRU status (Active or Backup).

Part Number—The FRU part number.

Serial Number—The FRU serial number.

To display the FRU Properties dialog box for a FRU, do one of the following:

Click the FRU’s row and select Product > FRU > FRU Properties.

Double-click a FRU.