220

Cannot retrieve switch

state.

The director or switch state cannot

be retrieved by the Element

Manager because the Ethernet

link is down or busy.

Retry the operation later. If the

condition persists, contact the next

level of support.

Cannot run diagnostics

on a port that is

failed.

Port diagnostics (loopback tests)

cannot be performed on a port

that has failed any previous

diagnostic (power-on diagnostic,

on line diagnostic, or loopback

test). The amber LED associated

with the port is illuminated to

indicate the failed state.

Reset the port and perform diagnostics

again.

Cannot run diagnostics

on an active E_port.

Port diagnostics cannot be

performed on an active E_port.

Run diagnostics on an E_port only

when it is not active.

Cannot run diagnostics

on a port that is not

installed.

Port diagnostics cannot be

performed on a port card that is

not installed.

Run diagnostics only on a port that is

installed.

Cannot run diagnostics

on a port card that is

not installed.

Port diagnostics (loopback tests)

cannot be performed on a port

that does not have a small form

factor (SFF) optical transceiver

installed.

Install a transceiver in the port and

perform diagnostics again.

Cannot run diagnostics

while a device is

logged-in to the port.

Port diagnostics (internal loopback

test) cannot be performed on a

port while an attached Fibre

Channel device is logged in.

Ensure the device is logged out and

perform diagnostics again.

Cannot run diagnostics

while a device is

logged-in to the port.

A device is logged in to the port

where a diagnostic test is

attempted.

Log out the device and run the

diagnostic test again.

Cannot save IPL

configuration while

active=saved is

enabled.

You cannot save the IPL file while

the active=saved property is set.

Disable the active=save property of the

FICON Management Server to allow

HAFM to save the IPL file.

Cannot save port

configuration.

The port configuration cannot be

saved at the Element Manager

because the Ethernet link is down

or busy.

Retry the operation later. If the

condition persists, contact the next

level of support.