HP StorageWorks 2.140 Director Switch User Manual

Page 65

background image

Director Element Manager user guide

65

The following messages display in the Reason field of the when an Invalid Attachment,

Segmented E_Port, or Inactive state occurs for the port:

Table 4

Messages in the Port Properties dialog box Reason field

Message

Description

Invalid attachment messages

01 Unknown

The reason is not known.

02 ISL connection not allowed
on this port

the ISL is connected to a port configured as an F_Port.

03 ELP rejected by the attached
switch

his switch transmitted an exchange link protocol (ELP)

frame that was rejected by the switch at the other end of

the ISL/

T

04 Incompatible switch other

end of the ISL

The switch is configured for Homogenous mode, and the

switch at the other end of the ISL is an HP switch

configured for Open Fabric 1.0 mode.

05 External loopback adapter
connected to the port

A loopback plug is connected to the port, and no

diagnostic test is running.

06 N_Port connection not
allowed on this port

he port type configuration does not match the actual port

use. (For example, the port is configured as an E_Port, but

attaches to a node device.)

T

07 Non-HP switch at other end

of the ISL

The cable is connected to a non-HP switch, and interop

mode is set to Open Fabric 1.0 mode.

08 ISL connection not allowed
on this port

the port type configuration does not match the actual port

use. (For example, the port is configured as an F_Port, but

attaches to a switch or director.)

10 Port binding violation -
Unauthorized WWN

The WWN entered to configure Port Binding for this port

is not valid, or a nickname was used that is not

configured for the attached device in the Element

Manager. Possible causes are:
Hardware problem on switch or on a connected node

where ELP frames are not delivered, the response is not

received, or a fabric login (FLOGI) cannot be received.

There may be problems in the switch SBAR.
Faulty or dirty cable connection.
Faulty host bus adapters (HBAs) that do not send out

FLOGI within a reasonable time frame.

0x0C ESA Security Mismatch

Processing of Exchange Security Attribute Frame detected

required security feature mismatch.

0x0D Fabric Binding Mismatch

Fabric Binding is enabled and detected a switch

connection with an incompatible fabric membership list.

Could also be the result of problems delivering EFMD ILS.