beautypg.com

HP MPX200 Multifunction Router User Manual

Page 232

background image

Table 34 MPX200 log messages (continued)

The FCIP route #n went down because
the Fibre Channel port on the remote
peer went down.

Error

FCIP

FcipRoute#%d: FC link on the

remote peer went down

172322

TCP link for FCIP route #n has been
established.

Info

FCIP

FcipRoute#%d: TCP Link Up

184515

FCIP link is up for FCIP route #n.

Info

FCIP

FcipRoute#%d: FCIP Link Up

184536

FCIP route #n: Incorrect VLAN
configuration.

Error

FCIP

FcipRoute#%d: VLAN Info

Unavailable

184542

Ethernet port was not able to negotiate
the configured speed.

Error

NIC

QL3xxx:%s: Auto Negotiation

error detected

205571

Ethernet port speed is not supported.

Error

NIC

QL3xxx:eth%d: Unsupported speed

portConfig 0x%x

205572

Ethernet device could not be
configured.

Error

NIC

QL3xxx:ql3xxx_probe: cannot

allocate ethernet device %s

206080

The Ethernet port was not able to
register as a network device, resulting

Error

NIC

QL3xxx:ql3xxx_probe: cannot

register network device %s

206089

in a port initialization error for the
specified network device.

The total number of TCP checksum
errors detected on the Ethernet link
belonging to the eth#%d port.

Error

NIC

QL3xxx:eth%d: TCP/IP checksum

error - TotalChecksumErrorCount

= %lu

206114

Ethernet port is operating at 100Mbps
speed.

Info

NIC

QL3xxx:%s: PHY Downshift

occurred

217856

Ethernet link is up.

Info

NIC

QL3xxx:%s: Link Up

217857

Ethernet link is down.

Info

NIC

QL3xxx:%s: Link Down

217858

Ethernet port is down.

Info

NIC

QL3xxx:%s Adapter Down

218389

Ethernet port is up.

Info

NIC

QL3xxx:%s Adapter Up

218401

Uncorrectable memory error detected
at address provided in log message.

Fatal

System

"memory monitor: Detected

Uncorrectable Ecc %08lx system

is rebooting in 5 secs\n"

233473

Attempt to register the interrupt
handler failed.

Fatal

System

"Failed to register interrupt

handler!\n"

233474

Failed class_simple_create
system call from memory monitor
initialization routine.

Fatal

System

"%s class_simple_create

failed\n"

233475

Failed to kill system task.

Error

System

"Failed to kill sys killer

%d\n"

237572

Router temperature has exceeded the
high temperature threshold.

Error

System

Temperature over high threshold

%d

237573

Router temperature has returned to the
normal operating range.

Info

System

Temperature is back to normal

range %d

249862

Table 35 DM log messages

Description

Msg type

Module type

Log Message

ID

An error occurred on an I/O that
was issued for a migration job.

Error

App

QLDM_HandleMigError: Migration

Job %d stopped for Src Lun %hd

44549

The description provides the job

Dest Lun %hd Error %x

232 Log messages