beautypg.com

HP MPX200 Multifunction Router User Manual

Page 218

background image

Table 34 MPX200 log messages (continued)

(router is target) in subsequent login
PDUs.

iSCSI login PDU was received with an
invalid TSIH value. The TSIH is invalid

Error

App

QLIS_LoginPduContinue: Session

does not exist, invalid TSIH

0x%x

41284

because there is no session with that
TSIH value. This would occur if the
iSCSI initiator attempting the login
failed to used the TSIH value provided
in the target login response PDU
(router is target) in subsequent login
PDUs.

iSCSI login rejected due to a CHAP
authentication error.

Error

App

QLIS_LoginPduContinue: Session

does not exist, invalid TSIH

0x%x

41353

iSCSI login rejected due to a CHAP
key error.

Error

App

QLIS_LoginPduContinue:

Unexpected CHAP key detected

41354

Failed to allocate an object for Set Port
Info IOCTL processing: PortType: 0 =

Error

App

QLBI_SetPortInfo:

QLUT_AllocatePortalObject

41508

FC, 1 = iSCSIPortId: 0 = FC1 or

failed (PortType 0x%x, PortId

0x%x)

iSCSI1(GE1), 1 = FC2 or iSCSI2
(GE2)

Inquiry command failed. The Inquiry
command was issued by the router as
part of its discovery process.

Error

App

QLBI_GetLunInfo: INQUIRY

failed, TPB status 0x%x

41626

Pass-Through command for Inquiry
command for page 83 failed. The

Error

App

QLBI_GetLunInfo: INQUIRY

failed, TPB status 0x%x

41629

Inquiry command was issued by the
router as part of its discovery process.

Pass-Through command for Read
Capacity command failed. The Read

Error

App

QLBI_Passthru: Invalid data

length %d bytes

41635

Capacity command was issued by the
router as part of its discovery process.

Read Capacity command failed. The
Read Capacity command was issued

Error

App

QLBI_GetLunInfo: INQUIRY

failed, TPB status 0x%x

41636

by the router as part of its discovery
process.

Pass-Through command issued by
management application (such as GUI)
was aborted.

Error

App

QLBI_GetLunInfo: INQUIRY

failed, TPB status 0x%x

41696

Pass-Through command issued by
management application (such as GUI)
failed due to invalid CDB length.

Error

App

QLBI_Passthru: Invalid CDB

length %d bytes

41700

Pass-Through command issued by
management application (such as GUI)
failed due to invalid data length.

Error

App

QLBI_Passthru: Invalid data

length %d bytes

41701

Pass-Through command issued by
management application (such as GUI)
was interrupted or timed out.

Error

App

QLBI_Passthru: Invalid data

length %d bytes

41717

IOCTL operation unsupported.
Operation code provided in log
message.

Error

App

QLBI_Ioctl: ERROR: Operation

(0x%x) not supported in this

mode

41750

Report LUNs command failed. The
Report LUNs command was issued by

Error

App

QLBI_GetLunList: REPORT LUNS

command failed

41768

218