Table 34 MPX200 log messages (continued)

iSCSI processor reported that the iSCSI
port NVRAM contains invalid data
(checksum error).

Error

iSCSI

#%d: QLIsrDecodeMailbox: NVRAM

invalid

74577

iSCSI processor reported a duplicate
IP address was detected (address xxxx
xxxx xxxx xxxx xxxx
).

Error

iSCSI

#%d: QLIsrDecodeMailbox: AEN

%04x, Duplicate IP address

detected, MB[1-5] %04x %04x

%04x %04x %04x

74580

iSCSI processor reported a link down
condition.

Error

iSCSI

#%d: QLIsrDecodeMailbox: Link

down

74587

Driver failed to receive a heartbeat
from the iSCSI processor for the
specified number of seconds.

Error

iSCSI

#%d: QLReadyTimer: Adapter

missed heartbeat for %d

seconds. Time left %d

74656

iSCSI processor (adapter) failed to
provide a heartbeat for x seconds.

Error

iSCSI

#%d: QLReadyTimer: Adapter

missed heartbeat for 0x%x

seconds

74659

iSCSI processor failed to complete an
abort request.

Error

iSCSI

#%d: QLReadyTimer: Abort

pTpb=%p failed, DrvCount 0x%x

74660

Driver timed out an iSCSI processor
operation and is aborting the
operation.

Error

iSCSI

#%d: QLTimer: Abort pTpb=%p,

Type %x, Timeout 0x%x DrvCount

0x%x, DdbIndex 0x%x

74661

Driver timed out an iSCSI processor
mailbox command.

Error

iSCSI

#%d: QLReadyTimer: MBOX_CMD

%04x %04x %04x %04x %04x %04x

%04x %04x timed out

74663

Driver timed out while attempting to
reconnect with the iSNS.

Error

iSCSI

#%d: QLReadyTimer:

QLiSNSReenable failed.

74665

iSCSI processor was restarted.

Error

iSCSI

#%d: QLProcessSystemError:

Restart RISC

74705

iSCSI processor rejected the firmware
initialize command.

Error

iSCSI

#%d: QLInitializeFW:

MBOX_CMD_INITIALIZE_FIRMWARE

74746

failed %04x %04x %04x %04x %04x

%04x

Driver’s initiator database is full. The
driver is capable of storing 1024

Error

iSCSI

#%d: QLUpdateInitiatorData: No

more room in Initiator

Database.

74784

iSCSI initiators in its database. Use
the CLI or GUI to remove
unwanted/unused iSCSI initiators.

Driver’s target database is full. Use the
CLI or GUI to remove
unwanted/unused iSCSI targets.

Error

iSCSI

#%d: QLSetTargetData: No more

room in Target Database.

74800

TCP retry for a frame failed on the
connection ddbIndex. Tpb contains
the frame memory address.

Error

iSCSI

#%d: ql_process_error:

OB_TCP_IOCB_RSP_W returned

DdbInx 0x%x pTpb %p

75008

Restart iSCSI processor (RISC).

Info

iSCSI

#%d: QLDisable: Restart RISC

86347

EEPROM updated, restart iSCSI
processor (RISC).

Info

iSCSI

#%d: QLEnable: Restart RISC to

update EEPROM

86349

Link up reported by iSCSI processor
for GE1 or GE 2.

Info

iSCSI

#%d: QLIsrDecodeMailbox: Link

up

86874

iSCSI controller reported a link
speed/configuration of 100 Mb
full-duplex (FDX).

Info

iSCSI

#%d: QLGetFwStateCallback: link

100Mb FDX

87346

223