beautypg.com

HP MPX200 Multifunction Router User Manual

Page 230

background image

Table 34 MPX200 log messages (continued)

Left power and cooling module (PCM)
is or has been installed.

Info

User

sysTempMon: Left PCM Installed

152129

Left PCM is or has been uninstalled.

Info

User

sysTempMon: Left PCM

Un-installed

152130

Right PCM is or has been installed.

Info

User

sysTempMon: Right PCM Installed

152131

Right PCM is or has been uninstalled.

Info

User

sysTempMon: Right PCM

Un-installed

152132

Left PCM is connected AC power.

Info

User

sysTempMon: Power for Left PCM

Plugged-in

152133

Left PCM is not connected to AC
power (unplugged).

Info

User

sysTempMon: Power for Left PCM

Un-plugged

152134

Right PCM is connected AC power.

Info

User

sysTempMon: Power for Right PCM

Plugged-in

152135

Right PCM is not connected to AC
power (unplugged).

Info

User

sysTempMon: Power for Right PCM

Un-plugged

152136

Left PCM (#1) is reporting a faulty fan.

Info

User

sysTempMon: Slot 1 (R1) PCM

Fan%d faulty

152137

Left PCM (#1) is reporting a healthy
fan.

Info

User

sysTempMon: Slot 2 (R2) PCM

Fan%d faulty

152138

Right PCM (#2) is reporting a faulty
fan.

Info

User

sysTempMon: Slot 1 (R1) PCM

Fan%d healthy

152139

Right PCM (#2) is reporting a healthy
fan.

Info

User

sysTempMon: Slot 2 (R2) PCM

Fan%d healthy

152140

Router has detected an over
temperature, Front: %dC Rear: %dC
CPU1: %dC CPU2: %dC.

Info

User

sysTempMon: Over Temperature

Front: %dC Rear: %dC CPU1: %dC

CPU2: %dC

152141

Fan(s) speed has been set to high.

Info

User

sysTempMon: Setting the fan

speed to high

152142

Fan(s) speed has been set to normal.

Info

User

sysTempMon: Setting the fan

speed to normal

152143

Router temperature has returned to
normal operating range, Front: %dC
Rear: %dC CPU1: %dC CPU2: %dC.

Info

User

sysTempMon: Temperature back to

safe value. Front: %dC Rear:

%dC CPU1: %dC CPU2: %dC

152144

Router has reached a critical
temperature ad is shutting down,

Info

User

sysTempMon: Critical

Temperature, Shutting Down

152145

Front: %dC Rear: %dC CPU1: %dC
CPU2: %dC.

Front: %dC Rear: %dC CPU1: %dC

CPU2: %dC

This is an informative message, not an
error. It indicates that an FCIP was
removed or modified.

Error

FCIP

FcipRoute#%d: Cleaning FCIP

Instance

172040

FCIP route #n has not been able to
communicate with the remote peer for
10 seconds.

Error

FCIP

FcipRoute#%d: Did not get the

keepalive msg form remote peer

172231

FCIP route #n local node is out of sync
with the remote peer.

Error

FCIP

FcipRoute#%d: Synchronization

Error on Receive

172238

FCIP route #n detected an error in
de-compression.

Error

FCIP

FcipRoute#%d: Decompression

Error on Receive

172239

230 Log messages