Pressed to indicate "PIPE MATERIAL". Because PVC
(factory set) is already registered, go to the next step.

Note: If the pipe is made of another material, press

ENT

key, and select a corresponding menu.

PIPE MATERIAL
PVC

ź

Pressed to indicate "WALL THICKNESS".

WALL THICKNESS
4.50 mm

ENT

ź

Pressed to blink the cursor.

WALL THICKNESS

0

04.50 mm

ź

Operated to compose "7.0" because, from piping data in
Section 6.6., the wall thickness of polyvinyl chloride pipe
(tap water size) is 7.0 mm.

WALL THICKNESS
007.

0

0 mm

Pressed to register the wall thickness.

WALL THICKNESS

½½ COMPLETE ½½

Ļ

ENT

ź
ź
ź
ź

--- “WALL THICKNESS” registered.---

WALL THICKNESS
7.00 mm

ź

Pressed to indicate "LINING MATERIAL".
"NO LINING" (factory set) is already registered.
Because there is no lining, go to the next step.

Note: If lining is provided, press

ENT

key, and select a

corresponding menu. Or, input a sound velocity.
Next, go to "LINING THICKNESS", and input a
lining thickness. Nothing is indicated in case of
"NO LINING".

LINING MATERIAL
NO LINING

ź

Pressed to indicate "KIND OF FLUID". Because
"WATER" (factory set) is already registered, go to the
next step.
Note: If fluid to be measured is other than water, press

ENT

key, and input the sea water or measurement

fluid's sound velocity.

KIND OF FLUID
WATER

ź

Pressed to indicate "KINEMATIC VISCO". Input the
kinematic viscosity of the fluid to be measured. Because
the kinematic viscosity 1.0038E–6 [m

2

/s] of water at 20

qC

is already registered, go to the next step. In case of fluid
other than water, input the kinematic viscosity at a
measurement status of fluid to be measurued referring to
data in Section 6.6., etc.

KINEMATIC VISCO
1.0038 E–6m2/s

ESC

ź

Pressed to indicate "PIPE PARAMETER". "S= 31" is
indicated on 2nd line. After mounting the frames on
piping, insert into it 2 sensor units spaced at 31 divisions.

PIPE PARAMETER
S= 31 ( 93mm)

ESC

Press

ESC

key once, and

key twice to resume

the measurement mode.

0.00 m3/h
+ 0.00 m3