beautypg.com

Installation of detector (sx3-a0, sx3-b0), Outline of detector installation procedure, How to treat the mounting surface – Dwyer UXF2 User Manual

Page 28: How to mount the frame

background image

- 18 -

3.5. Installation of detector (SX3-A0, SX3-B0)

3.5.1. Outline of detector installation procedure

(1) Treat the surface to mount on the detector.
(2) Mount the frame.
(3) Mount the sensor unit.

3.5.2. How to treat the mounting surface

By thinner, sandpaper, etc., eliminate rust, pitch, convex and concave from the pipe surface to mount on the detector by the
frame length to occupy.
Note: 1. If jute is wound on the pipe, peel off the jute over the entire periphery by frame length (L) + 200 mm

beforehand.

Jute winding

Pipe

L+200mm

Fig. 3-1 L: Frame length (SX3-A0: 228 mm, SX3-B0 348 mm)

3.5.3. How to mount the frame

z

Mount the frame carefully not to cut your fingers with stainless steel belt.

(1) Pass the spring fixture on the stainless steel belt as

shown in Fig. 3-2.

Spring fixture

Stainless steel belt

Fig. 3-2

(2) Pass the stainless steel belt through 2 belt holes on

the frame as shown in Fig. 3-3.

Frame

Fig. 3-3

BULLETIN F-70