2.2.2. Mounting position

The detector can be installed vertically, horizontally or in any position provided the following:

(1) The piping must completely be filled with fluid when it flows.

Pump

Air tends to accumulate.

Good

Good

May not
completely be
filled with liquid.

May not completely be filled with liquid.

(2) In case of horizontal piping, mount the detector within

r45q from the horizontal plane. Otherwise, the measurement

could be impossible if bubbles stay in the upper part of piping or if deposits are accumulated in the lower part of
piping. In case of vertical piping, the detector may be mounted at any position on its periphery provided that the
flow is upward.

Horizontal

Pipe

45

°

45

°

(3) Do not mount the detector on a distorted part, flange or welding.

Weldment

Welding is included.

Weldment

Off the Welding.

Welding is partly involved.

Avoid Welding.

BULLETIN F-70