Caution on installation location – Dwyer UXF2 User Manual
Page 6
- iv -
(1) Sufficient space is required for daily inspection, proper wiring, etc.
(2) A location not exposed to direct sunshine nor weathering.
(3) Isolation from excess vibration, dust and moisture.
(4) A location not subjected to radiated heat from a heating furnace etc.
(5) A location not subjected to corrosive atmosphere
(6) A location not to be flooded
(7) A place remote from electrical devices (motor, transformer, etc.) which generate electromagnetic
induction noise, electrostatic noise, etc.
(8) A location not subject to excessive fluid pulsation (near pump discharge side)
(9) A location that provides sufficient flow conditioning with the length of the straight pipe.
(10)A place where ambient temperature and humidity are • 20 to +50qC and 90% RH or less for flow
transmitter, and • 20 to +60qC and 90% RH or less for detector set.
CAUTION ON INSTALLATION LOCATION
BULLETIN F-70
- 166T (1 page)
- 160S (2 pages)
- PAFS-1000 (1 page)
- 160F (2 pages)
- Mark II WSI (4 pages)
- MW-1 (2 pages)
- 89088 (12 pages)
- 660 (2 pages)
- 670 (16 pages)
- FLST (4 pages)
- AFG (6 pages)
- FAFM (2 pages)
- DAFM (2 pages)
- STRA (4 pages)
- 530 (2 pages)
- AVFS (2 pages)
- 641RM (4 pages)
- 641B (4 pages)
- 641 (4 pages)
- VTT (2 pages)
- SFI-700 (2 pages)
- GFM (32 pages)
- GFC (40 pages)
- DMF (44 pages)
- GFM2 (20 pages)
- GFM3 (22 pages)
- TFP-LI (30 pages)
- TFP-GI (27 pages)
- TBS (7 pages)
- HFT (4 pages)
- CAM (6 pages)
- PWD (3 pages)
- BAT (3 pages)
- FPCA (4 pages)
- FPCA (2 pages)
- SPK (4 pages)
- MFS (8 pages)
- LOFM (3 pages)
- FLMG (12 pages)
- MFS2 (16 pages)
- PFT (4 pages)
- IPFS (7 pages)
- UFB (48 pages)
- UFC (56 pages)
- Series PUB (44 pages)