beautypg.com

How to replace the fuse – Dwyer UXF2 User Manual

Page 103

background image

- 93 -

5.3. How to replace the fuse

zTurn off power before replacing the fuse.
zFuse specifications and replacement

(1) AC power source model (100 or 200 V): 5.2 mm (diameter)

u 20 mm (long), 250 V, 0.5 A.

P/N FGMB: 250 V, 0.5 A MFG: FTI Co. Ltd. (OEM) or equivalent.

(2) DC power sourcemodel: : 5.2 mm (diameter)

u 20 mm (long), 250 V, 1 A.

P/N FGMB: 250 V, 1 A MFG: FTI Co. Ltd. (OEM) or equivalent.

(1) Opening the cover after turning off power

Loosen 4 screws from the flow transmitter front, and open the cover.

(2) Replacing the fuse

Detach the fuse holder from the power supply board, and replace the fuse. Then, return the fuse holder in place.

(3) Closing the cover

Close the cover, and tighten 4 screws.

zDo not energize power to the unit until the cover is secured..