beautypg.com

How to remove the sensor unit (sx3-a0, sx3-b0) – Dwyer UXF2 User Manual

Page 44

background image

- 34 -

3.8. How to remove the sensor unit (SX3-A0, SX3-B0)

If the sensor unit has to be detached from the frame such as for changing the spacing between the sensor units, proceed as
follows:

(1) Loosen the wing nut located at the middle of the

frame with 3 to 4 turns (Fig. 3-39).

Note 1: Do not loosen the wing nut completely.

Fig. 3-39

(2) By hand, hold the frame close to the pressing fixture

for a sensor unit to release.
Press the plastic section which extends from the
frame of the sensor unit just enough to open the
frame a little (about 1 mm). At this time, the claws
of the sensor unit fixture are disengaged from the
frame (Fig. 3-40).

Note 2: Do not open the frame excessively. Otherwise,

it may bend, so reinstalling the sensor may be
difficult or the frame may become deformed.

Fig. 3-40

(3) Disengage the opposite claws of the sensor unit

pressing fixture from the frame (Fig. 3-41).

Fig. 3-41

(4) Ensure the claws are disengaged from both sides, and

remove the sensor unit from the frame (Fig. 3-42).

Fig. 3-42

(5) Repeat this procedure for the other sensor.

Note 3: After removing both sensor units, retighten the

loosened wing nut.

BULLETIN F-70