5.7.4. If analog output is abnormal
Symptom Cause
Remedy
Current output is
wrong.
Range setting is wrong.
z
Set the range correctly.
Not 4 mA when
measurement value is 0.
Analog output is misadjusted.
z
Calibrate the analog output.
Output is 0 mA.
Cable is open-circuited.
Output is over 20 mA.
"OVERFLOW" is indicated on LCD.
Range over.
z
Recheck and set range data of
analog output.
Output is below 4 mA.
"UNDERFLOW" is indicated on
LCD.
Back flow
z
Set the upstream and downstream
properly.
Measurement value
varies but analog output
is constant.
Output load is above 600
:.
z
Lower the load below 600
:.
Analog output does not
match the measurement
value.
Analog output is misadjusted.
z
Calibrate the analog output.
Output remains
unchanged even after
analog output calibration.
Hardware error.
z
Contact manufacturer.
BULLETIN F-70
- 166T (1 page)
- 160S (2 pages)
- PAFS-1000 (1 page)
- 160F (2 pages)
- Mark II WSI (4 pages)
- MW-1 (2 pages)
- 89088 (12 pages)
- 660 (2 pages)
- 670 (16 pages)
- FLST (4 pages)
- AFG (6 pages)
- FAFM (2 pages)
- DAFM (2 pages)
- STRA (4 pages)
- 530 (2 pages)
- AVFS (2 pages)
- 641RM (4 pages)
- 641B (4 pages)
- 641 (4 pages)
- VTT (2 pages)
- SFI-700 (2 pages)
- GFM (32 pages)
- GFC (40 pages)
- DMF (44 pages)
- GFM2 (20 pages)
- GFM3 (22 pages)
- TFP-LI (30 pages)
- TFP-GI (27 pages)
- TBS (7 pages)
- HFT (4 pages)
- CAM (6 pages)
- PWD (3 pages)
- BAT (3 pages)
- FPCA (4 pages)
- FPCA (2 pages)
- SPK (4 pages)
- MFS (8 pages)
- LOFM (3 pages)
- FLMG (12 pages)
- MFS2 (16 pages)
- PFT (4 pages)
- IPFS (7 pages)
- UFB (48 pages)
- UFC (56 pages)
- Series PUB (44 pages)