How to set the total unit, Bulletin f-70 – Dwyer UXF2 User Manual
Page 86
- 76 -
4.6.3. How to set the total unit
Description
z
Select the totalizer unit of volume.
z
Metric system
Total··························· mL (factory set), L, m
3
, km
3
, Mm
3
, mBBL, BBL, kBBL
z
Inch system
Total··························· gal, kgal, ft
3
, kft
3
, Mft
3
, mBBL, BBL, kBBL, ACRE-in, ACRE-ft
For actual keying, refer to the typical operation indicated below. Set the parameter protection to OFF beforehand
(Section 4.4.1).
Typical operation Set the total unit to [m
3
].
Keying order
Description
Indication
ź
Pressed 3 times to indicate "MEASURE SETUP".
MEASURE SETUP
ENT
ź
Pressed to indicate "SYSTEM UNIT".
SYSTEM UNIT
METRIC
ź
Pressed twice to indicate "TOTAL UNIT".
TOTAL UNIT
mL
ENT
ź
Pressed to blink.
TOTAL UNIT
mL
ź
Pressed twice to select "m
3
".
TOTAL UNIT
m3
Pressed to register it.
TOTAL UNIT
½½ COMPLETE ½½
Ļ
ENT
ź
ź
ź
ź
--- "m
3
" registered.---
TOTAL UNIT
m3
ESC
Press
ESC
key once, and
key twice to resume
the measurement mode.
0.00 m3/h
+ 0.00 m3
BULLETIN F-70