Dwyer UXF2 User Manual

Page 78

background image

- 68 -

4.5.7.4. How to validate the alarm output

Description
z

Select a contact output as DO1 and/or DO2 when received wave or EEPROM is abnormal.

Settable range

ALL

: Select a contact output when EEPROM and received wave (none or unstable) are

abnormal.

HARDWARE FAULT : Select a contact output when EEPROM is abnormal.
PROCESS ERROR

: Select a contact output when received wave is abnormal.

For actual keying, refer to the typical operation indicated below. Set the parameter protection to OFF beforehand
(Section 4.4.1).

Typical operation Set the DO1 output to "PROCESS ERROR". Also set the contact to Normally OFF.

Keying order

Description

Indication

ź

Pressed twice to select the OUTPUT SETUP mode.

OUTPUT SETUP

ENT

ź

Pressed to indicate ZERO ADJUST.

ZERO ADJUST
CLEAR

ź

Pressed 5 times to indicate "DO1 OUT".

* Pressing

key again will select "DO2".

DO1 OUT
NOT USED

ENT

ź

Pressed to blink the cursor.

DO1 OUT

NOT USED

ź

Pressed 4 times to indicate "ALARM" on 2nd line.

DO1 OUT

ALARM

ENT

ź

Pressed to indicate the ALARM selection screen.

ALARM

ALL

ź

Pressed twice to indicate "PROCESS ERROR".

ALARM

PROCESS ERROR

Pressed to register it.

ALARM

½½ COMPLETE ½½

Ļ

ENT

ź
ź
ź
ź

--- "PROCESS ERROR" registered.---

STATUS OUT

CONTACT ACTION

ENT

ź

Pressed to indicate "CONTACT ACTION".

CONTACT ACTION

ACTIVE ON

Pressed to register "ACTIVE ON" (normally OFF).

* If it is desired to select Normally ON, press

key.

CONTACT ACTION

½½ COMPLETE ½½

Ļ

ENT

ź
ź
ź
ź

--- "ACTIVE ON" registered.---

STATUS OUT

CONTACT ACTION

ESC

Press

ESC

key twice, and

key 3 times to resume

the measurement mode.

0.000 m/s
0.000 m3/h

BULLETIN F-70