Piping data, Bulletin f-70 – Dwyer UXF2 User Manual
Page 122
- 112 -
6.3. Piping data
Stainless steel pipe for pipe arrangement (JIS G3459-1988)
Nominal
diameter
(mm)
Outer
diameter
(mm)
Normal thickness
Schedule
5S
Schedule
10S
Schedule
20S
Schedule
40
Schedule
80
Schedule
120
Schedule
160
Thickness
(mm)
Thickness
(mm)
Thickness
(mm)
Thickness
(mm)
Thickness
(mm)
Thickness
(mm)
Thickness
(mm)
A
B
25
34.0
1.65
2.8
3.0
3.4
4.5
—
6.4
32
42.7
1.65
2.8
3.0
3.6
4.9
—
6.4
40
48.6
1.65
2.8
3.0
3.7
5.1
—
7.1
50
60.5
1.65
2.8
3.5
3.9
5.5
—
8.7
65
76.3
2.1
3.0
3.5
5.2
7.0
—
9.5
80
89.1
2.1
3.0
4.0
5.5
7.6
—
11.1
90
101.6
2.1
3.0
4.0
5.7
8.1
—
12.7
100
4
114.3
2.1
3.0
4.0
6.0
8.6
13.5
125
5
139.8
2.8
3.4
5.0
6.6
9.5
15.9
150
6
165.2
2.8
3.4
5.0
7.1
11.0
18.2
200
8
216.3
2.8
4.0
6.5
8.2
12.7
23.0
250
10
267.4
3.4
4.0
6.5
9.3
15.1
28.6
300
12
318.5
4.0
4.5
6.5
10.3
17.4
33.3
350
14
355.6
—
11.1
19.0
35.7
400
16
406.4
—
12.7
21.4
40.5
500
20
508.0
—
15.1
26.2
50.0
—
—
—
—
—
—
11.1
12.7
14.3
18.2
21.4
25.4
27.8
30.9
450
18
457.2
—
14.3
23.8
45.2
—
—
34.9
38.1
15
21.7
1.65
2.1
2.5
2.9
3.9
—
5.5
20
27.2
1.65
2.1
2.5
2.9
3.9
5.5
—
550
22
558.8
—
15.9
28.6
54.0
—
—
41.3
600
24
609.6
—
17.5
34.0
59.5
—
—
46.0
650
26
660.4
—
18.9
34.0
64.2
—
—
49.1
Polyethylene pipe for city water (JIS K6762-1982)
Galvanized steel pipe for city water SGPW (JIS G3442-1988)
Outer
diameter
(mm)
Thickness
(mm)
Weight
(kg/m)
25
34.0
5.0
0.423
3.5
0.322
30
42.0
5.5
0.586
4.0
0.458
40
48.0
6.5
0.788
4.5
0.590
50
60.0
8.0
1.210
5.0
0.829
Nominal
diameter
(mm)
1st type (Soft pipe)
Thickness
(mm)
Weight
(kg/m)
2nd type (Hard pipe)
20
27.0
4.0
0.269
3.0
0.217
13
21.5
3.5
0.184
2.5
0.143
1
1
1
2
2
3
3
4
5
6
8
10
12
1
4
1
2
1
2
1
2
Outer diameter
(mm)
Thickness
(mm)
25
34.0
3.2
32
42.7
3.5
40
48.6
3.5
50
60.5
3.8
Nominal pipe
65
80
90
100
125
150
200
250
300
76.3
89.1
101.6
114.3
139.8
165.2
216.3
267.4
318.5
4.2
4.2
4.2
4.5
4.5
5.0
5.8
6.6
6.9
(B)
(A)
3
4
20
27.2
2.8
1
2
15
21.7
2.8
1
1
1
2
2
3
3
1
4
1
2
1
2
1
2
3
4
1
2
BULLETIN F-70