beautypg.com

Outline of product, Outline, Measuring principle – Dwyer UXF2 User Manual

Page 11: Bulletin f-70

background image

- 1 -

1. OUTLINE OF PRODUCT

1.1. Outline

This flowmeter is a clamp-on type ultrasonic flowmeter for permanent use based on transit time measuring methods. The
UXF2 is ideal for clean liquids containing no air bubbles such as pure water. The easy-to-use compact and
lightweight design is intended for integration into mechanical devices.
The flowmeter is applicable to small and medium size pipes of diameter range from 25mm to 600mm providing superior cost
performance.

1.1.1. Measuring principle

Measuring principle

Ultrasonic pulses are propagated diagonally from the upstream and downstream sides, and the time difference caused by the
flow is detected to provide the flow rate measurement.

Detector

Flow velocity

θ

t1

t2

D

Flow
transmitter

Output signal

Upstream sensor

Downstream sensor

Mounting the detector

Ultrasonic transducer

Pipe

Plastic wedge

Lining

Configuration diagram

(1) Single-path system (V method)

Detector

Signal cable

Power supply

4 to 20mA
DC

Contact

Flow
transmitter

(2) Single-path system (Z method)

Detector

Power supply

4 to 20mA
DC

Contact

Flow
transmitter

Signal cable

(3) When synchronizing

Power supply

Power supply

Detector

Signal cable

Signal cable

4 to 20mA
DC

Contact

(master)

(slave)

Flow
transmitter

Flow
transmitter

Detector

Synchronizing

signal wiring

4 to 20mA
DC

Contact

BULLETIN F-70