4.5.6.3. TOTAL mode (total reset, start, stop)

Description
z

The total is started, stopped or reset.

z

Settable range: START, STOP, RESET.
START: Carried out the total.
STOP: Stops the total.
RESET: Reset the total memory to the preset value.

Notes

1. A resetting action simultaneously resets both forward total memory and reverse total memory.
2. To start a total after resetting a total value, be sure to set the "START".

For actual keying, refer to the typical operation indicated below. Set the parameter protection to OFF beforehand
(Section 4.4.1).

Typical operation Reset the total value (preset value 0 m

3

), and restart a total.

Keying order

Description

Indication

0.00 m3/h
+ 127.26 m3

ź

Pressed twice to indicate "OUTPUT SETUP".

OUTPUT SETUP

ENT

ź

Pressed to indicate "ZERO ADJUST".

ZERO ADJUST
CLEAR

ź

Pressed 4 times to indicate "RANGE".

RANGE
FLOW RATE

ENT

ź

Pressed to blink the cursor.

RANGE

FLOW RATE

ź

Pressed to indicate "TOTAL" on 2nd line.

RANGE

TOTAL

ENT

ź

Pressed to indicate "TOTAL MODE".

TOTAL MODE
START

ENT

ź

Pressed to blink the cursor.

TOTAL MODE

START

ź

Pressed twice to indicate "RESET".

TOTAL MODE

RESET

Pressed to execute "RESET".
Note: After resetting, the total operation automatically

stops. To resume a total, execute "START".

TOTAL MODE

½½ COMPLETE ½½

Ļ

ENT

ź
ź
ź
ź

--- RESET has ended.---

TOTAL MODE
STOP

ENT

ź

Pressed to blink the cursor.

TOTAL MODE

STOP

ź

Pressed twice to indicate "START".

TOTAL MODE

START

BULLETIN F-70