App index dsplay functons, Other functons, Computaton functon (/m1 opton) – Yokogawa µR20000 User Manual
Page 53
1-37
IM 04P02B01-01E
Funct
onal
Explanat
on
and
Setup
Gu
de
1.10 Functon Setup Gude
1
2
3
4
5
6
7
8
9
10
11
12
App
Index
Dsplay functons
Item
Descrpton
Reference
Secton
Display brightness
Use
Aux > Brghtness > Dsplay in Setting mode to set the display brightness.
6.11
Bar graph display mode
Use
Bar graph in Basic Setting mode to set the bar graph display mode.
7.9
Display type
Assigns the display type on the data display setup
Screen number.
Chapter 8
Date format
Same as the Date format in “Recording functions.”
7.19
Other functons
Item
Descrpton
Reference
Secton
Key lock
• Target keys and password
7.10
Use
Keylock in Basic Setting mode to set the keys to be key-locked and the
password.
• Enable the key lock
3.13
Use
Func > Keylock in Operation mode and select Use or Not.
Customized menu
• Selecting the FUNC key display menu
7.20
Use
Select menu > Functon in Basic Setting mode to select the menus to be
displayed.
• Selecting the displayed menu of Setting mode
7.21
Use
Select menu > Set mode in Basic Setting mode to select the menus to be
displayed.
• Executing the customize menu
7.22
Use
Cust. menu in Basic Setting mode to set whether to use the customized menu.
If Use is selected, only the menus set to ON in the menu selection are displayed, and
Basic Setting mode is locked.
If Not is selected, all menus are displayed, and the Basic Setting mode lock is
released.
Language
Use
Language in Basic Setting mode to set the display and printout language.
7.14
Internal light brightness
Use
Aux > Brghtness > Lght in Setting mode to set the internal light brightness.
6.11
Computaton functon (/M1 opton)
Item
Descrpton
Reference
Secton
Computing equation and recording span
Use
Math > Formula in Setting mode to set the computing equation and recording
span for each channel.
9.2
TLOG computation
If TLOG computation is selected, use
Math > Tmer in Basic Setting mode to set the
timer operation
9.12
Use
Math > TLOG > Tmer number in Setting mode to set the timer used on each
computation channel.
9.6
Unit
Use
Math > Unt in Setting mode to set the unit for each channel.
9.3
Constants
Use
Math > Constant in Setting mode to define constants to be used in the computing
equations.
9.4
Alarms
Use
Math > Alarm in Setting mode to set the alarm for each channel.
9.5
• Delay high limit alarm/delay low limit alarm
• Alarm type
7.15
Use
Personalze > Add functon > Alarm delay in Basic Mode and select Use
or Not (common with measurement channels).
If Use is selected, delay high limit alarm and delay low limit alarm become
selectable under
Math > Alarm > Type in Setting mode. If Not is selected, alarm
delay cannot be selected.
• Alarm delay time
9.11
Use
Math > Aux > Alarm delay tme in Setting mode to set the alarm delay
time.
Record by setting recording zone
Use
Math > Aux > Zone in Setting mode to set the recording zone for each channel.
9.7
Partial expanded recording Use
Partal in Basic Setting mode and select Use or Not.
7.13
If Use is selected, set the display mode using
Math > Aux > Partal in Setting mode.
9.8
If Not is selected, the
Math > Aux > Partal item does not appear.