beautypg.com

App index, Fail output, Chart end output – Yokogawa µR20000 User Manual

Page 45

background image

1-29

IM 04P02B01-01E

Funct

onal
Explanat

on

and
Setup

Gu
de

For the procedure to set the functions, see section 1.10, “Function Setup Guide.”

1

2

3

4

5

6

7

8

9

10

11

12

App

Index

1.7 FAIL/Chart End Detecton and Output Functon

(/F1 Opton)

FAIL Output

When a failure occurs in the CPU of the recorder, a relay contact signal (1 signal) is
output. The relay is energized when the CPU is normal and de-energizes when a CPU
failure occurs. Therefore, relay output is carried out also when the power is turned OFF
(including a power failure). This relay behavior cannot be changed.

• FAIL Relay Output

NO

C

NC

Normal

NO

C

NC

Failure

NO

C

NC

Power-OFF

NO: Normally Opened, C: Common, NC: Normally Closed

Chart End Output

When the remaining amount of chart paper falls to approximately 2 cm, recording is
stopped, and the relay contact signal (1 relay) is output. The relay is energized in this
case. This relay behavior cannot be changed.

NO

C

NC

Normal

NO

C

NC

Chart end

NO

C

NC

Power-OFF

NO: Normally Opened, C: Common, NC: Normally Closed