Prntout, Prntout example on the pen model – Yokogawa µR20000 User Manual
Page 32
IM 04P02B01-01E
For the procedure to set the functions, see section 1.10, “Function Setup Guide.”
1-16
1.4 Recordng
Prntout
The figure below is used to explain the printout contents. The actual printout and font
are different from those illustrated in the figure. The printout positions are also slightly
different.
Prntout Example on the Pen Model
Recording start printout
Alarm printout
Message printout
New chart speed printout
Manual printout
Periodic printout
Time tick
Recording color
Scale
Buffer overflow mark
Time tick cancel mark
Offset compensation mark
Alarm
Delta computation
Nov.09.04 15:00
1 223.5mg/cm
3
2 437.2µS/cm
3 H 591.6°C
4 -0.222V
Nov.09.04!
13:50*
1 218.7mg/cm
3
2 390.6µS/cm
3 H 598.4°C
4 d -0.222V
0.0
500.0
1CH
mg/cm
3
RED
50mm/h_
08:00*25mm/h
09:52*START#205 ABCDEF
1H3*10:09
1H3 10:05
50mm/h*14:55
Tme tck
A time tick is a mark that indicate the position of the date/time on the chart paper.
Tme tck cancel mark
An exclamation point (!) is printed when the periodic printout time tick was not printed at the
correct position.
Channel number or tag prntout
Channel numbers or tags can be printed.
Setting the periodic printout (interval, reference time, types of measured values, and
periodic printout ON/OFF): Section 7.8
Turning printout ON/OFF (alarm printout, recording start printout, new chart speed
printout, scale printout for periodic printout, and recording color printout for
periodic printout): Section 7.7
Setting the time format (alarm printout, message printout, recording start printout, and
new chart speed printout): Section 7.16
Turning periodic printout ON/OFF for each channel: Section 6.6
Executing manual print: Section 3.7
Setting the message string and printing messages: Sections 6.8 and 3.10
Clearing the alarm printout buffer: Section 3.9
Printing settings: Section 3.8